ArcPad 48 Integral/Wireless DMX (SmartWhite)
6
Ensure that the structure to which you are attaching
the fixture is secure
Caution:
Overhead installation requires experience. Fixtures may cause severe injuries when crashing down! If you
have doubts concerning the safety of a possible installation, do not install the device and consult installation with
an expert.
Warning!
The antenna must be instaled on the fixture to keep declared IP rating of the fixture!
3.2 Connection to the mains
Fixtures must be installed by a qualified electrician in accordance with all national
and local electrical and construction codes and regulation.
The ArcPad 48 Integral/W is equiped with with a 5-cored power/data cable. The 3 cores serve for the power
supply and next 2 shielded cores are intended for DMX connection.
The power cores are coloured according to the following table.
Core
Connection
Plug Terminal Marking
Brown
Live
L
Light blue
Neutral
N
Yellow/Green
Earth
This device falls under class one and must be grounded!
The data cores (DMX) are coloured according to the table:
Core
Connection
Red
Data +
White
Data -
Shielding
Data ground
The power cable is connected to a junction box as shown on the picture below.