A n r it s u
4 3
♦
Note that the scanner reports the 32 strongest channels from the selected GSM channels.
Channel style
defines the style of the measured channel. For GSM the options are 200 kHz
and 30 kHz narrow.
Data mode
defines the type of measurement data computed from each sample. Note that the
available selection depends on the scanner type.
•
RX Level Average: the data reported is the average RX level, in dB, of the number of
samples.
•
RX Level Maximum: the data reported is the maximum RX level, in dB, of the number of
samples.
•
RX Level Minimum: the data reported is the minimum RX level, in dB, of the number of
samples.
•
RX Level Standard Deviation: the data reported is the standard of deviation of the
number of samples reported as an integer.
•
RX Level 10%: the data reported is the 10th percentile RX level, in dB, of the number of
samples.
•
RX Level 50%: the data reported is the 50th percentile RX level, in dB, of the number of
samples.