60
05/2008 Rev. 0.6
Service menu continued…
Main item
Sub item
Item
Range
Set
Description
2.13 Addit. settings
From
software 2.0
moved to menu
2.4.10
Waste manag.
Cup amount
0-1000
250
After reaching the set total of brewer
movements, dispensing is disabled and
the display reads: Out of order – Waste
bin full
Almost full sign.
0-1000
230
After reaching the set total of brewer move-
ments, the display reads:
Waste bin almost
full
Time-out reset
0-50 sec.
15 s
The length of time that the waste bin is al-
lowed to be removed (for emptying). When
replacing it the (internal) waste bin counter is
reset. Any display messages disappear.
Waste bin sign..
Yes/no
Yes
Turns off waste bin sensor software (bypass).
Drip tray sign.
Yes/no
Yes
Turns off drip tray sensor software.
Cycle counter
xxxxx
0-99999
This Cycle counter records the number of
vends the brewer has made. Tip: This counter
can be reset after maintenance if the brewer
has been checked.
Reset c. counter
Reset counter?
Reset Cycle counter (Brewer)
Perm.filter coun
xxxxx
0-10.000
6000
When the set number of (Brewer) vends is
reached the display reads ‘Replace perma-
nent filter’ when switching on.
Reset p. filter
Reset counter?
Reset the permanent filter counter after
(preventative) replacement
PIN Code Table
No.
Pincode
No.
Pincode
1
3
4
2
4
2
11
1
3
3
3
2
2
3
1
4
3
4
12
1
2
4
1
3
3
4
1
3
4
3
13
4
3
1
2
1
4
4
3
2
3
2
14
1
1
1
4
2
5
2
3
3
4
1
15
2
1
2
1
1
6
4
2
1
3
1
16
1
2
2
3
3
7
2
4
2
4
4
17
3
4
1
4
4
8
2
3
2
4
1
18
4
1
4
3
3
9
2
4
3
2
3
19
3
1
2
4
1
Table 1
10
3
1
3
3
2
20
2
2
3
2
4
Water Hardness Table
Water
Quality
Hardness
Limescale
Indicator ...cups
°D
°F
mmol/l
mgCaCo3/l
Very hard
18-30
32-55
3,2-5,3
321- 536
5000
Hard
12-18
22-32
2,2-3,2
214-321
8500
Average
8-12
15-22
1,4-2,2
268-214
12.500*
Soft
4-8
7-15
0,7-1,4
72-268
20.500
Table 2
Very soft
0-4
0-7
0- 0,7
0-72
0 = off