58
05/2008 Rev. 0.6
Service menu continued….
Main item
Sub item
Sub
Range
Description
2.7 Hardware test
Inputs
Temperature
Boiler temp
Shows the status of the sensors/switches
indicated
Level sensors
High Yes/no
Low Yes/no
Drip tray sensor
Yes/no
Waste bin
Yes/no
Door switch
Yes/no
Brewer switch
Yes/no
Key switch
Yes/no
Outputs
Test by holding
in recipe button
11.
# During test the
display shows
the Nominal
current (mA)
When the
Nominal current
of a output rises
above the set
current *
mentioned output
will be shut off.
Caution: BM 1
goes through a
complete drinks
cycle.
KW1
* 400 mA
Inlet valve (Boiler)
DV1
Dispenser valve 1 (Brewer)
DV2
Dispenser valve 2 (Mixer 2)
DV3
Dispenser valve 3 (Mixer 3)
DV4
Dispenser valve 4 (Hot water)
DV5
Dispenser valve 5 (n/a)
DV6
Inlet valve 6 (Cold water) optional!
IM1 #
* 400 mA
Ingredients motor 1 (Canister 1)
IM2 #
Ingredients motor 2 (Canister 2)
IM3 #
Ingredients motor 3 (Canister 3)
IM4 #
Ingredients motor 4 (Canister 4)
IM5 #
Ingredients motor 5 (Canister 5)
IM6 #
Ingredients motor 6 (Canister 6)
BM/MM1 #
* 800 mA
Brewer motor
MM2 #
Mixer motor 2
MM3 #
Mixer motor 3
Ventilator
* 200 mA
Ventilator
LED’s
LED’s
Calib. valves
Test by holding
in recipe button
11 (for 1 sec.)
to open the rel-
evant valve for
10 seconds.
DV1
15 ml / sec
Calibrate to 150 ml (10 sec x 15 ml)
DV2
15 ml / sec
Calibrate to 150 ml (10 sec x 15 ml)
DV3
15 ml / sec
Calibrate to 150 ml (10 sec x 15 ml)
DV4
20 ml / sec
Calibrate to 200 ml (10 sec x 20 ml)
DV5
20ml / sec.
Calibrate to 200ml (10sec. x 20ml)
(Optional valve for Brewer By-pass)
DV6
42 ml / sec
Inlet valve cannot be calibrated (fixed flow)