10
2017/05 Rev. 0.0
ComBi-Line
Component
Image
Cold water reservoir [07971] + lid [12349]
with level sensors for the brew system only (models CB)
The left side is used for the cold water inlet for the coffee system.
Cold water reservoir [07971] + lid [12348]
with level sensors for the brew system and the hot water system
(models CB W)
The left side is used for the cold water inlet for the coffee system.
The right side is used for the cold water inlet for the hot water
boiler.
Both sides share one overflow outlet.
Reed contact [03063]
Controls the position of the swivel arm and the coffee containers.
Boiler heating element
Manufactured entirely from the material AISI 304.
Heating element CB5W [03220]
230 V 1100 W
Heating element CB10W/20W [1006294]
230 V 2000 W
See chapter 5.2
for operation.
Boil-dry protection boiler system [03106]
Activation temperature: 130 °C / 3 pole / manual reset.
This 3-pole thermal thermostat cuts off all heating elements when
the boiler heating elements run dry.
NTC sensor [80063]
Measures the boiler water temperature.
Fixed onto the outer side of the tank.