background image

5000M Crusader G Upgrade Installation Guide

 

 

P/N 70000549B 

 
 

  

 

All rights reserved. Subject to change without notice. 

14-February-03 

Network Connection Installation 

To install the network connection, plug the standard CAT5, 8-pin, RJ-45 
connector into the RJ-45 plug located on the back of the console.  The 
CNC provides access to network drives via Ethernet.   

Procedure: 

1.  Use a standard CAT5, RJ-45 cable for the network connection.  

Refer to 

Figure 1

.  

Network Connection

230002252

 

Figure 1, Console Rear Panel 

Refer to 

CNC Network Setup

, P/N 70000483, for an overview of network 

setup.  

 

NOTE:

  A qualified networking engineer must set up the networking 

software.  Software varies based on the type of network 
operating system used. 

 

 

Содержание 5000M

Страница 1: ...the following parts 1 One 5000M Console to match your existing Crusader G A7533006 3 Axis Level 1 A7553002 5 Axis Level 2 2 Software Package A4530016 3 Axis Software Package or A4550015 5 Axis Softwar...

Страница 2: ...ring connecting the servo to the card cage The Servo Reset are located on the new console and will be disconnected from the existing Servo Cabinet The RS 232 connection is a standard 9 Pin DB computer...

Страница 3: ...abel it P6 vi Remove the 110 VAC cable connected to the Power Supply Hot Neutral and Ground c Remove the RS 232 plug from the servo cabinet wall It is directly connected to the card cage and will prev...

Страница 4: ...m the PCB 801 P7 connector Replace with the yellow wire from TB3 3 also inserted into a 3 position plug Make sure the yellow wire is on Pin 3 5 Connecting the AC Cable 36000271 to the Interface board...

Страница 5: ...iffers from the specifications that follow you will need to modify the Setup Utility in the appropriate sections See the 5000M CNC Setup Utility Manual P N 70000509 for further instructions a Builder...

Страница 6: ...ter Parameter tables g Builder Setup General Axis Vector Limits Default is Not Enabled If you have Vector Limits enable them accordingly h Builder Setup Basic I O Interface I O Nodes Can Node 0 Inputs...

Страница 7: ...Bit 4 SMT 5 Bit 5 Can Node 2 Outputs Sink SMT 6 Bit 0 SMT 7 Bit 1 S Strobe Bit 2 M Strobe Bit 3 T Strobe Bit 4 k Tuning the system The servo system is ready to be turned on once you have verified the...

Страница 8: ...plug located on the back of the console The CNC provides access to network drives via Ethernet Procedure 1 Use a standard CAT5 RJ 45 cable for the network connection Refer to Figure 1 Network Connecti...

Страница 9: ...olt P N 86100853 Procedure NOTE You must complete changes to Setup Utility parameters before you can operate the Remote Start Stop To install the Remote Start Stop Option 1 Locate the Start Stop pushb...

Страница 10: ...vates Select Ext Start and press ENTER The CNC may prompt for a password If necessary enter the service level password and press ENTER Refer to 5000M CNC Setup Utility Manual P N 70000509 Password Res...

Страница 11: ...u D I O Nodes Setup Menu I O Nodes Setup 1 DSP2 Node 2 CAN Node 0 3 CAN Node 1 DSP2 Input 0 Setup Function States Curr Bit 1 Ext Start 2 Ext Stop 3 Auto Man 2 CAN I O 10 000 Yes Basic I O Interface Se...

Страница 12: ...unction States Curr Bit 1 Ext Start 2 Ext Stop 3 Auto Man 2 Menu E DSP2 Input 0 Setup Menu 1 Off 2 Active Low 3 Active High Menu F Options Setup Menu DSP2 Node Setup 1 Input 0 2 Input 1 3 Input 2 Menu...

Страница 13: ...nly Handy Pulser Kit including preassembled Handy Pulser one 10 32 x 3 8 inch shoulder bolt P N 86100853 and mounting bracket P N 23000178 33000965 for 3 4 and 5 axes systems Handy Pulser Kit includin...

Страница 14: ...NDWHEEL connector 7 Plug the Handy Pulser cable into the back of the console at the Handwheel connector Refer to Figure 1 Console Rear Panel Figure 5 illustrates the harness handwheel connector Table...

Страница 15: ...n these procedures may require you to enter a service level password Refer to 5000M CNC Setup Utility Manual P N 70000509 Password Restricted Parameters To configure the handwheel in the Handy Pulser...

Страница 16: ...Menu A Setup Options Menu Setup Options 1 Builder Setup Startup Screen Software Options Menu 2 Setup Utility Software Options Menu D Handwheel DRO 1 Setup Menu Options None Handwheel Linear DRO Rotar...

Страница 17: ...ing a keyboard deactivates the console keypad To reactivate the keypad unplug the keyboard The operator cannot activate the E STOP function or reset the servos using an external keyboard These functio...

Страница 18: ...mends that you replace the console filter every three months However under some adverse environmental conditions such as oil vapor contamination and or high levels of particulate more frequent filter...

Отзывы: