14-February-03 

  

Remote Start/Stop Configuration 

1. Refer to 

Figure 2, Remote Start/Stop Setup Map

.  In Manual Mode 

and with the control turned on, press the red 

Emergency Stop

 button; 

then, press 

EXIT

 (

F10

) to display the 

Software Options Menu

.  

2. In the 

Software Options Menu

, highlight 

Setup Utility

, and press 

ENTER

3. The 

Setup Options Menu, Menu A

, activates. 

4. Select 

Builder Setup

, and press 

ENTER

5. The 

Builder Setup Menu, Menu B

, activates.  Select 

Basic I/O 

Interface

, and press 

ENTER

6. The 

Basic I/O Interface Setup Menu, Menu C

, activates.  Select 

I/O 

Nodes

, and press 

ENTER

7. The 

I/O Nodes Setup Menu, Menu D

, activates.  Select 

DSP2 Node

and press 

ENTER

.  Refer to 

Figure 3, DSP

2

 Node Setup Menu

8. The 

DSP2 Input 0 Setup Menu, Menu E

, activates.  Select 

Ext Start

and press 

ENTER

.  (The CNC may prompt for a password.  If 

necessary, enter the service level password, and press 

ENTER

.  Refer 

to 

5000M CNC Setup Utility Manual

, P/N 70000509, “Password 

Restricted Parameters,” for more information.) 

9. The 

Options Setup Menu, Menu F

, activates.  Select 

Active High

and press 

ENTER

10. The 

DSP2 Input 0 Setup Menu, Menu G

, activates.  Select 

BIT

 (

F1

), 

and press 

ENTER

11. The 

DSP2 Node Setup Menu, Menu H

, activates.  Select 

Input 1

and press 

ENTER

12. The 

DSP2 Input 1 Setup Menu, Menu I

, activates.  Select 

Ext Stop

and press 

ENTER

13. The 

Options Setup Menu, Menu J

, activates.  Select 

Active Low

14. Press 

EXIT

 (

F10

) successively until the 

Save Changes?

 prompt 

appears in the middle of the screen. 

15. Select 

Yes

 (

F1

) to save the changes made. 

16. Enter control software and verify that the Start and Stop button on the 

push button station function the same way as the green and red 

START

 and 

STOP

 keys on the keyboard. 

 

NOTE:

  The Start/Stop device must be plugged in.  If it is not, the inputs 

activated above must be set to off. 

Содержание 5000M

Страница 1: ...the following parts 1 One 5000M Console to match your existing Crusader G A7533006 3 Axis Level 1 A7553002 5 Axis Level 2 2 Software Package A4530016 3 Axis Software Package or A4550015 5 Axis Softwar...

Страница 2: ...ring connecting the servo to the card cage The Servo Reset are located on the new console and will be disconnected from the existing Servo Cabinet The RS 232 connection is a standard 9 Pin DB computer...

Страница 3: ...abel it P6 vi Remove the 110 VAC cable connected to the Power Supply Hot Neutral and Ground c Remove the RS 232 plug from the servo cabinet wall It is directly connected to the card cage and will prev...

Страница 4: ...m the PCB 801 P7 connector Replace with the yellow wire from TB3 3 also inserted into a 3 position plug Make sure the yellow wire is on Pin 3 5 Connecting the AC Cable 36000271 to the Interface board...

Страница 5: ...iffers from the specifications that follow you will need to modify the Setup Utility in the appropriate sections See the 5000M CNC Setup Utility Manual P N 70000509 for further instructions a Builder...

Страница 6: ...ter Parameter tables g Builder Setup General Axis Vector Limits Default is Not Enabled If you have Vector Limits enable them accordingly h Builder Setup Basic I O Interface I O Nodes Can Node 0 Inputs...

Страница 7: ...Bit 4 SMT 5 Bit 5 Can Node 2 Outputs Sink SMT 6 Bit 0 SMT 7 Bit 1 S Strobe Bit 2 M Strobe Bit 3 T Strobe Bit 4 k Tuning the system The servo system is ready to be turned on once you have verified the...

Страница 8: ...plug located on the back of the console The CNC provides access to network drives via Ethernet Procedure 1 Use a standard CAT5 RJ 45 cable for the network connection Refer to Figure 1 Network Connecti...

Страница 9: ...olt P N 86100853 Procedure NOTE You must complete changes to Setup Utility parameters before you can operate the Remote Start Stop To install the Remote Start Stop Option 1 Locate the Start Stop pushb...

Страница 10: ...vates Select Ext Start and press ENTER The CNC may prompt for a password If necessary enter the service level password and press ENTER Refer to 5000M CNC Setup Utility Manual P N 70000509 Password Res...

Страница 11: ...u D I O Nodes Setup Menu I O Nodes Setup 1 DSP2 Node 2 CAN Node 0 3 CAN Node 1 DSP2 Input 0 Setup Function States Curr Bit 1 Ext Start 2 Ext Stop 3 Auto Man 2 CAN I O 10 000 Yes Basic I O Interface Se...

Страница 12: ...unction States Curr Bit 1 Ext Start 2 Ext Stop 3 Auto Man 2 Menu E DSP2 Input 0 Setup Menu 1 Off 2 Active Low 3 Active High Menu F Options Setup Menu DSP2 Node Setup 1 Input 0 2 Input 1 3 Input 2 Menu...

Страница 13: ...nly Handy Pulser Kit including preassembled Handy Pulser one 10 32 x 3 8 inch shoulder bolt P N 86100853 and mounting bracket P N 23000178 33000965 for 3 4 and 5 axes systems Handy Pulser Kit includin...

Страница 14: ...NDWHEEL connector 7 Plug the Handy Pulser cable into the back of the console at the Handwheel connector Refer to Figure 1 Console Rear Panel Figure 5 illustrates the harness handwheel connector Table...

Страница 15: ...n these procedures may require you to enter a service level password Refer to 5000M CNC Setup Utility Manual P N 70000509 Password Restricted Parameters To configure the handwheel in the Handy Pulser...

Страница 16: ...Menu A Setup Options Menu Setup Options 1 Builder Setup Startup Screen Software Options Menu 2 Setup Utility Software Options Menu D Handwheel DRO 1 Setup Menu Options None Handwheel Linear DRO Rotar...

Страница 17: ...ing a keyboard deactivates the console keypad To reactivate the keypad unplug the keyboard The operator cannot activate the E STOP function or reset the servos using an external keyboard These functio...

Страница 18: ...mends that you replace the console filter every three months However under some adverse environmental conditions such as oil vapor contamination and or high levels of particulate more frequent filter...

Отзывы: