![Anilam 5000M Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/anilam/5000m/5000m_installation-manual_2943796010.webp)
5000M Crusader G Upgrade Installation Guide
P/N 70000549B
All rights reserved. Subject to change without notice.
10
14-February-03
Remote Start/Stop Configuration
1. Refer to
Figure 2, Remote Start/Stop Setup Map
. In Manual Mode
and with the control turned on, press the red
Emergency Stop
button;
then, press
EXIT
(
F10
) to display the
Software Options Menu
.
2. In the
Software Options Menu
, highlight
Setup Utility
, and press
ENTER
.
3. The
Setup Options Menu, Menu A
, activates.
4. Select
Builder Setup
, and press
ENTER
.
5. The
Builder Setup Menu, Menu B
, activates. Select
Basic I/O
Interface
, and press
ENTER
.
6. The
Basic I/O Interface Setup Menu, Menu C
, activates. Select
I/O
Nodes
, and press
ENTER
.
7. The
I/O Nodes Setup Menu, Menu D
, activates. Select
DSP2 Node
,
and press
ENTER
. Refer to
Figure 3, DSP
2
Node Setup Menu
.
8. The
DSP2 Input 0 Setup Menu, Menu E
, activates. Select
Ext Start
,
and press
ENTER
. (The CNC may prompt for a password. If
necessary, enter the service level password, and press
ENTER
. Refer
to
5000M CNC Setup Utility Manual
, P/N 70000509, “Password
Restricted Parameters,” for more information.)
9. The
Options Setup Menu, Menu F
, activates. Select
Active High
,
and press
ENTER
.
10. The
DSP2 Input 0 Setup Menu, Menu G
, activates. Select
BIT
(
F1
),
and press
ENTER
.
11. The
DSP2 Node Setup Menu, Menu H
, activates. Select
Input 1
,
and press
ENTER
.
12. The
DSP2 Input 1 Setup Menu, Menu I
, activates. Select
Ext Stop
,
and press
ENTER
.
13. The
Options Setup Menu, Menu J
, activates. Select
Active Low
.
14. Press
EXIT
(
F10
) successively until the
Save Changes?
prompt
appears in the middle of the screen.
15. Select
Yes
(
F1
) to save the changes made.
16. Enter control software and verify that the Start and Stop button on the
push button station function the same way as the green and red
START
and
STOP
keys on the keyboard.
NOTE:
The Start/Stop device must be plugged in. If it is not, the inputs
activated above must be set to off.