- 20 -
C1
39
60
36
00
.fm
IT
AUS
SDE
FR
ES
Before carrying out any replacement procedure, acti-
vate all the safety devices provided and decide
whether staff at work and those in the vicinity should
be informed. In particular, turn off the gas supply tap
and prevent access to all devices which might cause
unexpected health and safety hazards if turned on.
If work parts have to be replaced, use original spare
parts only.
The manufacturer declines all responsibly for injury or
damage to components due to the use of non original
parts, or extraordinary work on the appliance which
may modify the safety requirements without the man-
ufacturer's authorisation.
When ordering components, follow the instructions
provided in the parts catalogue.
To carry out this operation, proceed as follows.
1- Turn off the gas supply tap.
2 - Open the door (
A
).
3 - Unscrew the nozzle (
B
) and replace it with the one
suitable for the type of gas in use (see table
at back of manual).
4 - Close the door (
A
).
To carry out this operation, proceed as follows.
1- Turn off the gas supply tap.
2 - Open the door (
A
).
3 - Unscrew the union (
B
).
4 - Extract the nozzle (
C
) and replace it with the one
suitable for the type of gas in use (see table at
back of manual).
5 - Screw the union (
B
) back in place and close the
door(
A
).
Important
This operation must be carried out by skilled
operatives in compliance with the legal re-
quirements with regard to safety at work.
Never dump non-biodegradable materials, lu-
bricating oils and non-metallic components
(rubber, PVC, resins, etc.) in the environ-
ment. Dispose of them in accordance with
the relevant legal requirements.
REPLACING PARTS
9
RECOMMENDATIONS FOR REPLACING PARTS
REPLACEMENT OF THE BURNER NOZZLE
REPLACEMENT OF THE PILOT LIGHT INJECTOR
DECOMMISSIONING THE APPLIANCE
A
B
IDM-39603311700.tif
IDM-39603311800.tif
A
B
C