- 4 -
IT
AUS
DE
FR
ES
TECHNICAL DATA
See tables and "Connection chart" at the back of the
manual.
SAFETY DEVICES
Although the appliance is complete with all safety de-
vices, during installation and connection additional
devices must be added if necessary to comply with
the relevant legal requirements.
The illustration shows the position of the devices.
A)Gas supply tap
:
for turning the connection to the
gas supply line on and off.
B)Safety thermocouple
:
cuts out the gas supply if the
flame goes out.
C)Safety thermostat
:
cuts off the gas supply in case of
overheating.
Caution - warning
Make a daily check that the safety devices are
properly installed and in good working or-
der.
SAFETY AND INFORMATION SIGNS
The illustration shows the position of the signs
provided.
A)General hazard
:
read the manual carefully be-
fore carrying out any procedure.
B)General hazard
:
describes the precautions to be
adopted during installation and commissioning.
C)Nameplate with manufacturer and appliance
data
.
STANDARD ACCESSORIES
Comes complete with the following:
A)
Well lid.
B)
Oil drain extension.
C)
Basket.
IDM-39603310400.tif
C
B
A
IDM-39603312200.tif
A
B
C
IDM-39603312000.tif
A
B
C