- 20 -
C
13
96
1
86
00
.fm
English
5 - Connect the circuit-breaker
(A)
to the terminal
board
(L)
of the appliance as shown in the dia-
gram and in the electrical system diagram at
the back of the manual.
Use a cable with at least H05RN-F characteris-
tics.
6 - Tighten the cable gland
(E)
.
Important
When connecting, take care over the con-
nection of the neutral and earth wires; if
they are not connected correctly, the burn-
er does not light.
7 - Replace the control panel
(D)
and the knobs
(B)
on completion of the operation.
The constructor has tested the appliance with its
own mains gas, identified by the sticker applied to
the nameplate.
If the type of gas to be connected is different from
that used for testing, proceed as follows.
1 - Turn off the gas supply tap
(A)
.
2 - Change the top burner nozzles (see page 24).
3 - Change the oven burner nozzle (see page 24).
4 - Change the top burner pilot light nozzles (see
page 25).
5 - Change the oven burner pilot light nozzle (see
page 25).
6 - Adjust the minimum setting on the gas control
valves of the hob burners (see page 21) and the
oven burner (see page 22).
7 - Remove the sticker from the nameplate and ap-
ply the new one to identify the gas being used.
Important
On completion of the operation, make sure
that there are no gas leaks or malfunctions.
CONVERSION OF GAS SUPPLY
IDM-39603614200.tif
A
IDM-3960200250.tif
IDM-39618600700.tif
C
B
A
D
F
E