Anest Iwata MSG-200 Скачать руководство пользователя страница 8

-8- 

 

 

 
 
 
 

Multi-spray  gun

   

 

 

 

     

  Important 

 

 
 
 
 

 
 

Be  sure  to  observe  warnings  and  cautions  in  this  instruction  manual. 

If  not,  it  can  cause  paint  ejection  and  serious  bodily  injury  by  drawing  organic  solvent. 

Be  sure  to  observe  following 

 

  marked  items  which  are  especially  important.

 

 

Indicates a potentially hazardous situation which, if not avoided, may result in serious injury or loss of life. 

 

Indicates  a  potentially  hazardous  situation  which,  if  not  avoided,  may  result  in  minor  or  moderate  injury  or 

property damage. 

  Important 

 

Indicates  notes  which  we  ask  you  to  observe.    The  safety  precautions  in  this  instruction  manual  are  the 

minimum necessary conditions.    Follow national and local regulations regarding fire prevention, electricity and 

safety as well as your own company regulations. 

 

Important specifications                                                                                                                                                                                                         

 

Max. Pressure 

Fluid 

  9.8MPa    /    98bar    /    1440PSI 

 

Max. Temperature   

 

Air

 

 

  0.68MPa    /    6.8bar    /    98PSI 

 

Atmosphere

 

 

5

℃~

40

 

Noise level 

69 dB(A)

 

 

Air

Fluid 

5

℃~

43

 

Spray condition 

Used

 

Nozzle

 

tip

   

 

 

;  NT2004CMU 

Atomizing  air  pressure  ;  0.15MPa  /  1.5bar  /  21.4PSI 

 

Fluid  pressure  ;  10MPa  /  100bar  /  1440PSI   
Tested  with  water 

 

 

 

Measuring point 

1m backwards from gun, 1.6 m height 

 

 

 

※ 

Atomizing  air  pressure  means  air  pressure  at  gun  inlet  when  trigger  is  pulled  and  air  flows

 

 
 

Main specifications 

                                                                                                                                                                                                                                                                                                   

Model 

Use 

Max.operating fluid 

pressure 

MPa 

(bar / PSI) 

Operating fluid 

pressure 

MPa 

(bar / PSI) 

Max.atomizing air 

pressure 

MPa 

(bar / PSI) 

Operating atomizing 

air pressure 

MPa 

(bar / PSI) 

Filter 

Size 

(mesh) 

Air & fluid 

connection 

Mass 

(lbs) 

MSG-200  General 

9.8 

(98 / 1440) 

4.9 

(49 / 720) 

0.68 

(6.8 / 98) 

0.15 

(1.5 / 21.4) 

#200 

G 1/4 

480 (1.06) 

   

Fluid output ; See 4.Selection of nozzle tip according to kind of paint.

 

 
 
 
 

   

This  Anest-iwata  multi-  spray  gun  kit  complies  to 

ATEX regulations 94/9/EC,   

Protection level 

 

2 G X

Suitable for use in Zones 1 and 2. 

X marking

  :

 

Any  static  electricity  discharge  from  the  multi- 

spray gun is to be diverted to the grounded 

the conductive fluid hose as stipulated. 

 

MSG-200

 

 

INSTRUCTION MANUAL 

   

 

This manual contains IMPORTANT WARNINGS and INSTRUCTIONS. 

  Equipment in this manual is exclusively for painting purposes. 

  Do not use for other purposes. 

  The operator shall be fully conversant with the requirements stated in this 

  instruction manual including important warnings, cautions and operation and 

  correct handling. 

  Read and understand the instruction manual, before use and retain for 

  reference.   

WARNING 

CAUTION 

Содержание MSG-200

Страница 1: ...kgf cm2 kgf cm2 kgf cm2 a kgf cm2...

Страница 2: ...mm...

Страница 3: ......

Страница 4: ......

Страница 5: ...20 3 20 2 min cm min cm cm cm MPa kgf cm2 kgf cm2 cm ml sec cm...

Страница 6: ...This warranty is valid only in Japan 9 00 12 00 13 00 17 00 http www anest iwata co jp...

Страница 7: ...P18 23 12 10 17 8 1 5 12 13 8 13 19 200 19 NT 2004CMU 223 8501 3176 http www anest iwata co jp No 1231 07 No 03522224...

Страница 8: ...ater Measuring point 1m backwards from gun 1 6 m height Atomizing air pressure means air pressure at gun inlet when trigger is pulled and air flows Main specifications Model Use Max operating fluid pr...

Страница 9: ...to multi spray gun Protection of human body 1 Use in a well ventilated site by using spray booth If not poor ventilation can cause organic solvent poisoning and catch fire If you feel any abnormality...

Страница 10: ...trigger makes air valve in gun body set open and atomizing air emits Pulling trigger further makes fluid valve at gun tip between fluid needle set and nozzle gland set open and paint emits Tightening...

Страница 11: ...e tip each tip is optional except attached NT 2004CMU Refer to 4 on page 13 and prepare nozzle tip separately Be sure to stop pump reduce fluid pressure down to 0 pressure and securely apply safety lo...

Страница 12: ...xt job WARNING During painting be sure to wear protective cover such as glasses mask or gloves to avoid serious injury caused by paint or solvent which might enter your eyes or you might inhale Be sur...

Страница 13: ...t 2 digits when you spray paints of high viscosity or easily clogged Refer to the below chart and select proper nozzle tip model fluid output l min pattern width cm NT 1502CMU NT 1503CMU NT 2002CMU NT...

Страница 14: ...y set fluid needle set fluid needle spring nozzle tip nozzle gland set air cap set 2 3 weak tightening 2 4 damage on seat damage on seat 14 weak spring 21 2 damage on seat dust on seat 1 weak tighteni...

Страница 15: ...1 3 body set 1 17 trigger screw 2 4 needle packing set 1 18 air adj set 1 4 1 washer 1 19 filter set 1 4 2 spring washer 2 19 1 filter case 1 4 3 packing holder 1 19 2 filter set 1 200 mesh 4 4 sub pa...

Страница 16: ...16 Manual No 1231 07 Code No 03522224 3176 Shinyoshida cho Kohoku Ku Yokohama 223 8501 Japan...