
-12-
3-4 Painting job
During painting, be sure to wear protective cover such as glasses,
mask or gloves to avoid serious injury caused by paint or solvent which
might enter your eyes or you might inhale.
H I N T
!
•As fluid pressure and air pressure increase, paint mist becomes finer
and finishing becomes better. But on the other hand, high pressure
can be dangerous, precipitate corrosion of equipment and nozzle tip,
increase spray mist and decrease transfer efficiency. Adjust
pressure to the lowest level possible (fluid pressure 4.9MPa,
atomizing air pressure 0.15MPa) as long as the finish is satisfactory.
•Adjust spray distance to nearest level possible as long as the finish is
satisfactory in order to reduce spray mist and increase transfer
efficiency.
3-5 Adjust spray pattern and delete tails
3-6 Solve clogging of nozzle tip
3-7 Cleaning and maintenance
Fully clean after job is finished in order to get longer lifetime and good performance at next
job.
WARNING
During painting, be sure to wear protective cover such as glasses,
mask or gloves to avoid serious injury caused by paint or solvent which
might enter your eyes or you might inhale.
Be sure to stop pump and reduce fluid pressure down to 0 pressure
before disassembling multi-spray gun.
Never use commercial or other parts instead of ANEST IW ATA original
spare parts.
Process
W here to clean
How to clean
Remarks
1
nozzle tip
Remove from gun and clean it.
refer to 3-3
2
fluid passage of
gun body
Clean fluid passage with cleaning liquid which is
compatible with paint being used.
3
filter set
①
Remove filter joint[20-3].
②
Remove filter set[20-2] and clean it.
refer to 7.7
WARNING
Adjust spray pattern
to get small
pattern, loosen
to get flat
pattern, tighten
till it stops
Pattern size and fluctuation
differ according to nozzle tip
Delete tails
tail
Tails appear according to
fluid viscosity and property.
When they appear, increase
atomizing air pressure a bit.
atomizing air press. High
when using attached cleaning needle.
Cleaning needle
When blowing with air by air nozzle of multi
spray unit after removing nozzle tip from air
cap set.
loosen
Содержание MSG-200
Страница 1: ...kgf cm2 kgf cm2 kgf cm2 a kgf cm2...
Страница 2: ...mm...
Страница 3: ......
Страница 4: ......
Страница 5: ...20 3 20 2 min cm min cm cm cm MPa kgf cm2 kgf cm2 cm ml sec cm...
Страница 6: ...This warranty is valid only in Japan 9 00 12 00 13 00 17 00 http www anest iwata co jp...
Страница 16: ...16 Manual No 1231 07 Code No 03522224 3176 Shinyoshida cho Kohoku Ku Yokohama 223 8501 Japan...