- 13 -
3. Selection of nozzle tip according to kind of paint
H I N T
!
<Numbering system>
Pattern width 20 cm at 25cm spray distance.
Fluid output 0.4ml/sec/cm of width at
fluid pressure 4.9MPa (0.49bar
/
7PSI)
NT-20 04 atomizing air pressure 0.15MPa (0.02bar
/
0.29PSI)
Use nozzle tip with large figures of last 2 digits when you spray paints of high
viscosity or easily clogged.
※
Refer to the below chart and select proper nozzle tip.
model
fluid output
l/min
pattern width
cm
NT-1502CMU
NT-1503CMU
NT-2002CMU
NT-2003CMU
NT-2004CMU
0.18
0.27
0.24
0.36
0.48
13 ~ 18
13 ~ 18
18 ~ 23
18 ~ 23
18 ~ 23
NT-2005CMU
NT-2503CMU
NT-2505CMU
0.60
0.45
0.75
18 ~ 23
23 ~ 28
23 ~ 28
NT-3003CMU
NT-3004CMU
NT-3005CMU
NT-3006CMU
NT-3503CMU
NT-3504CMU
NT-3505CMU
0.54
0.72
0.90
1.08
0.63
0.84
1.05
28 ~ 33
28 ~ 33
28 ~ 33
28 ~ 33
33 ~ 38
33 ~ 38
33 ~ 38