-15-
CAUTION
Motor burnout
Before doing any wiring, check electric source and voltage.
ISP-50-SV1 is AC100V class.
Voltage can not be changed.
Check your electric source, voltage, and wire correctly to receptacle.
Improper wiring and incorrect voltage can cause motor burnout.
Check voltage
Danger of problem recurrence and failure
If motor protective device or thermal protector activates, be sure to turn off
electric source and inspect causes to solve the problem.
Do not operate until problem is solved.
Operation while problem is left unsolved can cause problem recurrence and failure.
Inspect cause of
problem
Chart-1
Single-phase 100V class specifications
-
Voltage
V
Frequency
Hz
Recommended
protective device (or
breaker) capacity
A
-
-
-
100
50
2.6
-
-
-
100
60
2.4
-
-
-
115
60
2.4
-
-
-