![andrews ECOflo EC230/600 Скачать руководство пользователя страница 47](http://html1.mh-extra.com/html/andrews/ecoflo-ec230-600/ecoflo-ec230-600_installation-and-service-manual_2942793047.webp)
Issue 2 14/07/16
47
Operating Instructions
5
5.2.2
Lighting instructions
1. STOP! read the safety information on the previous page.
2. Set the thermostat to lowest setting.
3. Turn off all electrical power to the appliance.
4. This appliance does not have a pilot. It is equipped with an
ignition device which automatically lights the burner. Do not
try to light the burner by hand.
5. Turn off the main power switch.
6. Wait 5 minutes to clear out any gas. If you smell gas, STOP!
Follow “II” in the safety information on the previous page.
If you do not smell gas go to the next step.
7. Set the thermostat to the desired setting.
8. Turn on main power.
5.2.3 To turn off the gas appliance
1. Set the thermostat to lowest setting.
2. Turn off main power switch.
During the winter season or any cold period, you may desire a
higher temperature setting to adjust for the cold incoming water.
This adjustment, however, may cause additional condensation to
form on the colder tank surface. This does not mean the tank is
leaking. During summer months, the warmer incoming water
temperatures will benefit the performance of your water heater
and reduce the amount of condensation developed.
Condensation does not mean your tank is leaking. Most of
reported tank leaks on installation’s are proven to be
condensation. To avoid unnecessary inconvenience and
expense, make sure the tank is actually leaking before
contacting Andrews Water Heaters.
Illuminated main
power switch
Fig. 22
5.3 Temperature adjustment
Caution
This water heater is equipped with an energy cut out
device to prevent overheating. Should overheating
occur or if the gas supply fails to shut off, turn off the
manual gas control valve to the appliance and call a
qualified service company.