109
MN024-010
TPRN
1 HE
1 HE
1 HE
Figure 4.1.10: The TPRN is provided
with a screwing hole on each front
corner, thus allowing proper fi xing to
the installation rack.
Figure 4.1.12:
Power supply and ground terminals
on the rear side of the TPRN subrack
Fig. 4.1.11: intra-subrack distance must
be at least 1HE to allow air circulation.
1-HE inter-subrack distances can be
properly fi lled through blind panels
The TPRN kit provides:
• 1 TPRN sub-rack
• suitable power cord (fi g. 4.1.9a)
• 1 standard RJ45 cable (fi g. 4.1.9b)
• 1 standard RS232 cable (male-female), 2m
(fi g. 4,1,9c)
• 1 CD Manual (fi g. 4,1,8d)
Firstly, insert the sub-rack into the cabinet and apply 4
screws (not provided) in order to fi x it (Fig. 4.1.10).
To ensure correct TPRN installation, distance between
the front door of the rack and the front side of the TPRN
should be at least 15cm, otherwise the RF and optical
cables could be damaged when cabinet door is closed.
Leave at least 1 HE distance between two subracks in
order to facilitate air circulation (see Fig. 4.1.11).
Leave at least a 1 HE free space between the bottom or
the top of the cabinet and the TPRNs (see Fig. 4.1.11).
Connect the ground to the safety ground terminal.
Then, connect the power supply connector to the mains
(see Fig. 4.1.12).
TPRN Installation
(a)
(b)
(c)
(d)
Figure 4.1.9: Some of the installation accessories provided with the
TPRN subrack: (a) suitable power cord; (b) standard RJ-45 cable;
(c) RS232 cable; (d) 1 Cd rom, including ION-B manuals
power
supply
ground
terminal
Содержание ION-B Series
Страница 1: ...IONTM B Series User Manual rel 24 10...
Страница 2: ......
Страница 9: ...9 MN024 010...
Страница 10: ...10 ION B User Manual 1 Introducing ION B...
Страница 15: ...15 MN024 010...
Страница 16: ...16 ION B User Manual 2 Equipment Overview...
Страница 28: ...28 ION B User Manual...
Страница 29: ...29 MN024 010 3 TFAx Remote Unit...
Страница 32: ...32 ION B User Manual TFAM Case A...
Страница 40: ...40 ION B User Manual TFAM Case A Figure 3 2 9 Case A layout with waal anchor quotes...
Страница 42: ...42 ION B User Manual TFAM Case A Figure 3 2 11 Layout of the TKA installation kit for TFAx Remote Unit Case A...
Страница 53: ...53 MN024 010 TFAM Case B Figure 3 3 9 Case B layout with wall anchor quotes...
Страница 55: ...55 MN024 010 TFAM Case B Figure 3 3 11 Layout of the TKA installation kit provided with Case B Remote Units...
Страница 64: ...64 ION B User Manual TFAM Case R...
Страница 69: ...69 MN024 010 TFAM Case R a b c Figure 3 4 5 Mounting the Case R Remote Unit Steps a c...
Страница 70: ...70 ION B User Manual TFAM Case R d e g f h Figure 3 4 5 Mounting the Case R Remote Unit Steps d h...
Страница 71: ...71 MN024 010 TFAM Case R i l Figure 3 4 5 Mounting the Case R Remote Unit Steps i l...
Страница 77: ...77 MN024 010 TFAM Case R2 a b c Figure 3 5 5 Mounting the Case R2 Remote Unit Steps a c...
Страница 78: ...78 ION B User Manual TFAM Case R2 d g Figure 3 5 5 Mounting the Case R2 Remote Unit Steps d h e f h...
Страница 79: ...79 MN024 010 TFAM Case R2 i l Figure 3 5 5 Mounting the Case R2 Remote Unit Steps i l...
Страница 91: ...91 MN024 010 TFAM Case F 1 3 2 3 1 Figure 3 6 4 Mounting the Case F Remote Unit Steps a b a b...
Страница 92: ...92 ION B User Manual TFAM Case F Figure 3 6 4 Mounting the Case F Remote Unit Steps c d c d...
Страница 98: ...98 ION B User Manual...
Страница 99: ...99 MN024 010 4 Rack based Master Unit...
Страница 100: ...100 ION B User Manual...
Страница 112: ...112 ION B User Manual TPRF...
Страница 123: ...123 MN024 010 TPRF Figure 4 2 13 Mechanical Layout for wall mounting the TPRF31 Fast MiniRack 2...
Страница 126: ...126 ION B User Manual TFLN...
Страница 154: ...154 ION B User Manual...
Страница 155: ...155 MN024 010 5 Con guration Examples...
Страница 163: ...163 MN024 010 6 Warning and Safety Requirements...
Страница 172: ...172 ION B User Manual 7 TECHNICAL SUPPORT...
Страница 175: ...175 MN024 010 Appendixes...