InfiLink 200 Installation Guide

Powering Up the InfiLink 200

Connect the AC power cable to an electrical power source and the 
InfiLink 200 starts automatically.  The following occurs:

1. The red power light to the right and vertical center of the InfiLink 

200 comes on.

2. The yellow TD light of any given pair immediately flashes when 

data is being transmitted to that particular Infinet port.

3. The green RD light of any given pair immediately flashes when data 

is being received from the corresponding branches of Infinet.  This 
may not happen immediately.

Technical Manuals Online! - http://www.tech-man.com

firealarmresources.com

Содержание InfiLink 200

Страница 1: ...Andover Controls Corporation i InfiLink 200 Installation Guide Electronic Version Controlling Tomorrow s World Technical Manuals Online http www tech man com firealarmresources com...

Страница 2: ...ndover Massachusetts 01810 All Rights Reserved Published by the Engineering Department at Andover Controls Corporation IMPORTANT NOTICE This product is subject to change without notice This document d...

Страница 3: ...twork of local controllers It first presents how to prepare the site including facts about proper ground ing then how to install the InfiLink 200 For basic information on local area networks LANs refe...

Страница 4: ...iv InfiLink 200 Installation Guide Technical Manuals Online http www tech man com firealarmresources com...

Страница 5: ...how to plan and set up your network refer to the EnergyNet and Infinet Configuration Guide Warranty Registration Your warranty is effective for 18 months starting on the date the system is shipped Wa...

Страница 6: ...uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause interference to radio communications It has been tested and found to comp...

Страница 7: ...ng two jumpers but for smoke control applications you must use 120 VAC 10 15 60 Hz You select the input voltage When you receive it it is set to 120 V Instructions for altering the input voltage are i...

Страница 8: ...k 200 Installation Guide We cannot guarantee that the control system will operate as documented unless you properly ground all controllers Technical Manuals Online http www tech man com firealarmresou...

Страница 9: ...raising the potential of the pipe with respect to the ground When lightning strikes in the area of the installation it drastically changes the potential of the earth Surges of much lower potential al...

Страница 10: ...ust be corrected Does not exist Is connected to a corroded or galvanized pipe Is connected using a small gauge wire smaller than 14 AWG 2 Be sure your InfiLink 200 is connected to the ground with a co...

Страница 11: ...d it easier to mount if you remove the cabinet cover and place it to one side Warning Never drill holes in the InfiLink 200 cabinet or board A metal shaving could easily short circuit the electronics...

Страница 12: ...ector are listed in the appendix 6 5 in 6 67 in 80 in from bottom edge Screw Hole Location From Edge to Center Is 50 in Full Height Is 8 00 in Full Width is 7 5 in 19 in from top edge 8 5 in with RS 2...

Страница 13: ...ove it to E3 so it jumpers TP2 to E3 2 Disconnect the jumper end from E1 to E3 and entirely remove it from the controller board Connecting the AC Power Warning Be sure the AC power is not connected to...

Страница 14: ...10 InfiLink 200 Installation Guide Figure 2 shows the location of the AC power connection Technical Manuals Online http www tech man com firealarmresources com...

Страница 15: ...00 RD TD 5 SHLD RD TD 4 SHLD RD TD 3 SHLD RD TD 1 SHLD RD TD 2 INPUT POWER F1 3A 250V SLOW BLOW INPUT VOLTAGE SELECTION 115V 230V TP2 E2 TP2 E3 E1 E3 RD TD RS 232 F3 F2 1 8A 19200 9600 2400 1200 300 B...

Страница 16: ...crew driver Figure 3 shows the position of the plate where to place the wire and how the screw fits on the plate You can see how the screw holds the plate in place once you tighten it 3 Place the whit...

Страница 17: ...00 to ensure proper shielding of the entire link The shield for Port 1 is not connected to earth ground on the board but the shields for Ports 2 through 5 are connected to earth ground Port 1 however...

Страница 18: ...ghten the screw down on it 6 Tighten the screw down on it until the screw holds the shield in place This shield is connected to earth ground 7 Wire the other end of the cable to the first Infinet cont...

Страница 19: ...0 You can connect two buildings with the Infinet by having modems at tached to InfiLink 200s in each building Before you can use special modems to connect Infinet you must have a conditioned clean ded...

Страница 20: ...e right and vertical center of the InfiLink 200 comes on 2 The yellow TD light of any given pair immediately flashes when data is being transmitted to that particular Infinet port 3 The green RD light...

Страница 21: ...nfiLink 200 Installation Guide A 1 Appendix RS 232 Port Pinouts Table A 1 shows the pinouts for the RS 232 port on the InfiLink 200 Technical Manuals Online http www tech man com firealarmresources co...

Страница 22: ...ink 200 Installation Guide Table A 1 Pinouts for RS 232 Port on InfiLink 200 Pin Number Purpose 4 Driving High 1 Chassis 2 TD 3 RD 7 GND 9 V 10 V 20 Driving High Technical Manuals Online http www tech...

Отзывы: