MAINTENANCE 

 

1. 

Do not drop this monitor or subject it to strong impact. 

2. 

Avoid high temperature and solarization. Do not immerse the monitor in water as this 

will result in damage to the monitor. 

3. 

If  this  monitor  is  stored  near  freezing,  allow  it  to  acclimate  to  room  temperature  before 

use. 

4. 

Do not attempt to disassemble this monitor. 

5. 

If you do not use the monitor for a long time, please remove the batteries. 

6. 

It  is  recommended  the  performance  should  be  checked  every  2  years  or  after  repair. 

Please contact the service center. 

7. 

Clean the monitor with a dry, soft cloth or a soft cloth squeezed well after moistened with 

water, diluted disinfectant alcohol, or diluted detergent. 

8. 

No  component  can  be  maintained  by  user  in  the  monitor.  The  circuit  diagrams, 

component part lists, descriptions, calibration instructions, or other information which will 

assist  the  user

’s  appropriately  qualified  technical  personnel  to  repair  those  parts  of 

equipment which are designated repairably can be supplied. 

9. 

The  monitor  can  maintain  the  safety  and  performance  characteristics  for  a  minimum  of 

10,000  measurements  or  three  years,  and  the  cuff  integrity  is  maintained  after  1,000 

open

–close cycles of the closure. 

10.  It  is  recommended  the  cuff  should  be  disinfected  2  times  every  week  if  needed  (For 

example, in hospital or in clinique). Wipe the inner side (the side contacts skin) of the cuff 

by a soft cloth squeezed after moistened with Ethyl alcohol (75-90%), then dry the cuff by 

airing. 

 

EXPLANATION OF SYMBOLS ON UNIT 

 

  Symbol for

” THE OPERATION GUIDE MUST BE READ”(The sign background colour: 

blue.The sign graphical symbol: white) 

   

Symbol for 

“WARNING”

 

      Symbol for 

“TYPE BF APPLIED PARTS” (The cuff is type BF applied part) 

    Symbol for 

“ENVIRONMENT PROTECTION – Waste electrical products should not be 

disposed of with household waste. Please recycle where facilities exist. Check with your local 

Authority or retailer for recycling advice

”. 

 

Symbol for “MANUFACTURER” 

 

Symbol for 

“COMPILES WITH MDD93/42/EEC REQUIREMENTS” 

 

                 

Symbol for 

“DATE OF MANUFACTURE”

 

Содержание KD-322

Страница 1: ...RS 2 INTENDED USE 3 CONTRAINDICATION 3 PRODUCT DESCRIPTION 3 SPECIFICATIONS 4 NOTICE 4 SETUP AND OPERATING PROCEDURES 6 1 BATTERY LOADING 6 2 CONNECTING THE CUFF TO THE MONITOR 6 3 APPLYING THE CUFF 6...

Страница 2: ...The highest value usually appears in the daytime and lowest one usually at midnight Typically the value begins to increase at around 3 00AM and reaches to highest level in the daytime while most peop...

Страница 3: ...egrated pressure sensor blood pressure and pulse rate can be measured automatically and non invasively The LCD display will show blood pressure and pulse rate The Electronic Blood Pressure Monitor cor...

Страница 4: ...on 90 RH 13 Environmental temperature for storage and transport 20 55 4 131 14 Environmental humidity for storage and transport 90 RH 15 Environmental pressure 80kPa 105kPa 16 Battery life Approx 540...

Страница 5: ...ted that you consult with your physician for accurate assessment 13 Please do not use the cuff other than supplied by the manufacturer otherwise it may bring biocompatible hazard and might result in m...

Страница 6: ...e 2 CONNECTING THE CUFF TO THE MONITOR Insert the cuff tubing connector into the socket in the left side of the monitor Make certain that the connector is completely inserted to avoid air leakage duri...

Страница 7: ...rtably Measurement a Be seated with your feet flat on the floor and don t cross your legs b Place palm upside in front of you on a flat surface such as a desk or table c The middle of the cuff should...

Страница 8: ...f the monitor manually h During measurement you can press the exhaust valve which is located in the front of the bulb to release the air Note Please consult a health care professional for interpretati...

Страница 9: ...itor 8 TROUBLESHOOTING 2 PROBLEM POSSIBLE CAUSE SOLUTION LCD Display shows EE The cuff was not properly applied or the rubber tube was bent or pressed Review the cuff applying and testing sections of...

Страница 10: ...iately qualified technical personnel to repair those parts of equipment which are designated repairably can be supplied 9 The monitor can maintain the safety and performance characteristics for a mini...

Страница 11: ...use in the electromagnetic environment specified below The customer or the user of the KD 322 should assure that it is used in such an environment Emissions test Compliance Electromagnetic environmen...

Страница 12: ...equency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment Table 3 For ME EQUIPMENT and ME SYSTEMS that are not LIFE SUPPORTING Gu...

Страница 13: ...radio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic enviro...

Страница 14: ...12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 For transmitters rated at a maximum output power not listed above the recommended separation distance d in meters m can be de...

Отзывы: