of  temperature will appear. Short press and release the  MEM button until 
the unit (

  or 

) that you prefer appears.   

 
9.  Short  press  the  S  button  to  choose  whether  to  delete  the  memory.  Short 

press and release the MEM button to delete the memory and the meter will 
automatically power off. If you don't want to delete the memory, short press 
the S button directly to turn off the meter. 

     

   

 

10. When you change the batteries, you have to readjust device parameter. 

 

Coding the Meter 

  Code  meter  before  using  it  for  the  first  time  and  every  time  you  change 

another vial of test strip. With the meter turned off, insert the code card and 
pull out after the OK appears on screen. 

  Before code the meter, make sure the test strip have not expired. 

 

Testing Your Blood Glucose Level     

Before testing, you will need the following items: 

  Glucose AG-605A Meter 

  AGS-1000 test strip 

  Adjustable Automatic Lancing Device 

  Sterile Lancet 

 

CAUTION: 

To reduce the chances of infection: 

 

Choose a clean, dry work surface. 

 

Never share a lancing device and lancet with another person. 

 

Always use a new and sterile lancet. Lancets are for single use only. 

 

Always use a new Test Strip. Test Strips are for single use only. 

 

Avoid getting lotion, oils, dirt or debris in or on the lancet and lancing device. 

 
Step 1 

Wash hands using soap and warm water. Rinse and dry thoroughly. 

Step 2 

Make sure you have coded the meter and loaded the needle into the lancing 
device.

 

Step 3 

Remove a Test Strip from the vial and replace the cap on the vial immediately. 

 

Step 4 

Insert  the  test  strip  into  the  test  strip  slot  of  the  meter.  The  meter  turns  on 
automatically, and the code number appears on the screen. 

Содержание AG-605A

Страница 1: ...m if it is not working properly or if it has suffered any damage Do not let the Blood Glucose Monitoring System come into contact with surfaces which are too hot to touch Do not block test ports nor p...

Страница 2: ...mm L 50mm W 22mm H 3 Weight 60g exclude batteries 4 Measuring method Amperometric technology using glucose oxidase 5 Measuring range 20 mg dL 600 mg dL 1 1 mmol L 33 3mmol L 6 Measurement unit mg dL o...

Страница 3: ...test strip Avoid making the liquid into the test strip and the button Avoid getting water or any other solution inside the meter Blood Sample The fresh capillary vessel whole blood finger tip blood or...

Страница 4: ...ize batteries and confirms well positive and negative extremely 3 Slide battery cover back into place Note Discard the used battery according to the local law Test Strip The Test Strips are designed t...

Страница 5: ...the date setting Short press and release the MEM button until the correct date appears 5 With the correct date on the display short press and release the S button to bring up the time setting The hou...

Страница 6: ...ired Testing Your Blood Glucose Level Before testing you will need the following items Glucose AG 605A Meter AGS 1000 test strip Adjustable Automatic Lancing Device Sterile Lancet CAUTION To reduce th...

Страница 7: ...Replace the end cap back on the body of the lancing device 5 Pull back on the cocking mechanism until it comes to a stop 6 Place the lancing device firmly against the sample site and press the release...

Страница 8: ...f the same result occurs consult your healthcare professional immediately Step 10 If a LO message appears on your display your Glucose Meter has detected that your blood glucose level is lower than 20...

Страница 9: ...t strip Control solution If long press the S button for about two seconds in step5 the CTL will appear on the screen which means that the test is under the CTL condition and the result will not be sto...

Страница 10: ...aning the andon Blood Glucose Monitoring System gently wipe the exterior surface using a damp soft cloth AVOID USING ANY ORGANIC SOLVENT for cleaning Discard the used lancet properly in accordance wit...

Страница 11: ...countdown The meter is calculating the result At the end of the count down the meter will display the test result No action required Blood glucose level is lower than 20mg dl 1 1mmol L The message in...

Страница 12: ...12 Display the result Do nothing Demonstrates the memory the serial number Do nothing Memory result demonstration Do nothing No memory in meter Do nothing Result display is end Do nothing...

Страница 13: ...libration Please contact us Use a used test strip Please use a new strip and re test Meter internal memory unit error Reinsert the CODE bottle please contact us if it appear for three time Environment...

Страница 14: ...e number printed on the Test Strip vial Incorrect Code numbers has been inputted into the Meter Insert the new CODE card to match the Code number on the Test Strip vial label Test results are inconsis...

Страница 15: ...15 15minutes before performing a new test The Meter countdown did not start Test Strip has not been inserted correctly Use a new Test Strip and redo the test...

Страница 16: ...erature limitation Expired Date Anti garbage Lotus Global Co Ltd 47 Spenlow House Bermondsey London SE16 4SJ Andon Health Co Ltd Register Address No 3 JinPing Street Ya An Road Nankai District Tianjin...

Отзывы: