background image

 

10 

off automatically. 

     

                                                                                                   

Care and storage for your system 

  Handle  the  Meter  with  care.  Dropping  or  throwing  the  Meter  may  cause 

damage to the device. 

  Don't  expose  the  andon  Blood  Glucose  Monitoring  System,  Test  strip, 

Control  solution,  to  extreme  conditions,  such  as  high  humidity,  heat, 
freezing cold or dust. 

  Always  wash  hands  with  soap  and  water  and  rinse  and  dry  completely 

before  handling  the  andon  Blood  Glucose  Monitoring  System  and  Test 
strip 

  When  cleaning the  andon  Blood  Glucose  Monitoring  System,  gently  wipe 

the exterior surface using a damp soft cloth. AVOID USING ANY ORGANIC 
SOLVENT for cleaning.

 

  Discard  the  used  lancet  properly  in  accordance  with  local

state

and 

federal law.

 

  The cleaning liquid include 10

bleacher, 70

alcohol and 10

ammonia.

 

 

IMPORTANT 

For  healthcare  professionals  using  this  system  on  multiple  patients,  please  be  aware 
that  all  items  that  come  in  contact  with  human  blood  should  be  handle  as  potential 
biohazards.  Users  should  follow  the  guidelines  for  prevention  of  blood-borne 
transmittable  diseases  in  a  healthcare  setting  for  potentially  infections  human  blood 
specimens. 

Содержание AG-605A

Страница 1: ...m if it is not working properly or if it has suffered any damage Do not let the Blood Glucose Monitoring System come into contact with surfaces which are too hot to touch Do not block test ports nor p...

Страница 2: ...mm L 50mm W 22mm H 3 Weight 60g exclude batteries 4 Measuring method Amperometric technology using glucose oxidase 5 Measuring range 20 mg dL 600 mg dL 1 1 mmol L 33 3mmol L 6 Measurement unit mg dL o...

Страница 3: ...test strip Avoid making the liquid into the test strip and the button Avoid getting water or any other solution inside the meter Blood Sample The fresh capillary vessel whole blood finger tip blood or...

Страница 4: ...ize batteries and confirms well positive and negative extremely 3 Slide battery cover back into place Note Discard the used battery according to the local law Test Strip The Test Strips are designed t...

Страница 5: ...the date setting Short press and release the MEM button until the correct date appears 5 With the correct date on the display short press and release the S button to bring up the time setting The hou...

Страница 6: ...ired Testing Your Blood Glucose Level Before testing you will need the following items Glucose AG 605A Meter AGS 1000 test strip Adjustable Automatic Lancing Device Sterile Lancet CAUTION To reduce th...

Страница 7: ...Replace the end cap back on the body of the lancing device 5 Pull back on the cocking mechanism until it comes to a stop 6 Place the lancing device firmly against the sample site and press the release...

Страница 8: ...f the same result occurs consult your healthcare professional immediately Step 10 If a LO message appears on your display your Glucose Meter has detected that your blood glucose level is lower than 20...

Страница 9: ...t strip Control solution If long press the S button for about two seconds in step5 the CTL will appear on the screen which means that the test is under the CTL condition and the result will not be sto...

Страница 10: ...aning the andon Blood Glucose Monitoring System gently wipe the exterior surface using a damp soft cloth AVOID USING ANY ORGANIC SOLVENT for cleaning Discard the used lancet properly in accordance wit...

Страница 11: ...countdown The meter is calculating the result At the end of the count down the meter will display the test result No action required Blood glucose level is lower than 20mg dl 1 1mmol L The message in...

Страница 12: ...12 Display the result Do nothing Demonstrates the memory the serial number Do nothing Memory result demonstration Do nothing No memory in meter Do nothing Result display is end Do nothing...

Страница 13: ...libration Please contact us Use a used test strip Please use a new strip and re test Meter internal memory unit error Reinsert the CODE bottle please contact us if it appear for three time Environment...

Страница 14: ...e number printed on the Test Strip vial Incorrect Code numbers has been inputted into the Meter Insert the new CODE card to match the Code number on the Test Strip vial label Test results are inconsis...

Страница 15: ...15 15minutes before performing a new test The Meter countdown did not start Test Strip has not been inserted correctly Use a new Test Strip and redo the test...

Страница 16: ...erature limitation Expired Date Anti garbage Lotus Global Co Ltd 47 Spenlow House Bermondsey London SE16 4SJ Andon Health Co Ltd Register Address No 3 JinPing Street Ya An Road Nankai District Tianjin...

Отзывы: