1. PREFACE 

This SERVICE MANUAL provides various servicing information, including the mechanical and electrical parts, 

etc. This room air conditioner was manufactured and assembled under a strict quality control system.   

The refrigerant was charged at the factory.    Be sure to read the safety precautions prior to servicing the unit. 

1.1 SAFETY PRECAUTIONS 

1. When servicing the unit, set the POWER SWITCH to OFF and unplug the power cord. 

2. Inspect the service cord for damage or wear. 

If a short circuit is found, replace all parts which have been overheated or damaged by the short circuit. 

3. After servicing the unit, make an insulation resistance test to protect the customer from being exposed to 

shock hazards. 

1.2 INSULATION RESISTANCE TEST 

1. Unplug the power cord and connect a jumper lead between the two (2) live pins. 

2. The grounding conductor (yellow/green) is to be open. 

3. Measure the resistance value with an ohm meter between the jumped lead and each exposed metallic part   

on the equipment at all the positions (except OFF) of the ROTARY SWITCH or POWER SWITCH. 

4. The value should be over 1M

.

1.3 FEATURES 

Water full alarm 

Anti-icing function at cooling mode. 

 

Restart relay protection for the compressor. 

Temperature sensor err self-diagnose. 

24 hours on/off mode time setting. 

Both temperature mode display 

Separate motor for indoor and outdoor system. 

Multiple uses: dehumidifying and cloth drying. 

Low temperature Drying operation. 

There are four casters on the bottom for easy 

movement. 

Only one exhaust pipe, which makes the A/C   

easier to use. 

Remote-controlled or gentle-touch keys for easy   

and comfortable use. 

Compressors of famous brands are adopted for   

reliability and low noise. 

The heating system uses PTC electrical heater   

and will not be affected by ambient temperature,   

which saves energy. 

Suitable for local cooling and heating. 

Condenser shower and large volume tank design. 

Long time to pour the tank. 

  Directly drainage available.

 

1.4 CONTROL LOCATIONS 

    For cooling only with electric heater models: 

M ODE

FAN  SPEED

F ULL

POWER

T EMP. ADJU ST 

T IM ER   ON

T I MER   OF F

 

For cooling only models: 

M OD E

FAN  SPEED

F ULL

PO WER

T EMP. ADJU ST 

T IM ER    ON

T IM ER    OF F

 

Содержание MPK1-09CR-QB8

Страница 1: ...ebsite www andico com au Service manual CAUTION BEFORE SERVICING THE UNIT READ THE SAFETY PRECAUTIONS IN THIS MANUAL ONLY FOR AUTHORISED SERVICE PERSONNEL MODELS MPK1 09CR QB8 MPK1 12ER QB6 MPK1 14ER...

Страница 2: ...NS 2 2 TROUBLE SHOOTING GUIDE 2 1 REFRIGERATION CYCLE DIAGRAM 4 2 2 ELECTRIC FUNCTION 4 2 3 TROUBLE SHOOTING GUIDE 6 3 WIRING DIAGRAM 3 1 WIRING DIAGRAM FOR COOLING ONLY MODELS 9 3 2 WIRING DIAGRAM FO...

Страница 3: ...d each exposed metallic part on the equipment at all the positions except OFF of the ROTARY SWITCH or POWER SWITCH 4 The value should be over 1M 1 3 FEATURES Water full alarm Anti icing function at co...

Страница 4: ...mp Low fan speed lamp Fan speed setting button Push this button to select fan speed High Med and Low POWE R Power button Push this button to start the unit FULL Water full alarm lamp Power lamp Remote...

Страница 5: ...tion for the compressor Water full alarm Anti icing function at cooling mode Temperature sensor err self diagnose Both temperature mode display 2 2 4 Protection 2 2 4 1 The compressor functions protec...

Страница 6: ...A TS 1 TS Electric heater OFF Temp down Tempup El ectric heater ON 2 2 9 Temperature display 2 2 9 1 The setting temperature will be displayed in Cooling and Heating mode The room temperature will be...

Страница 7: ...peed to low speed Replace the motor if the speed does not change Refrigerant The amount of the refrigerant is too much making the compressor load too big Recycle and recharge the refrigerant after che...

Страница 8: ...ange tubing not to contact cabinet compressor shroud and barrier Water tank full Check and pour if the water tank is full Water depth sensor if failure Check and replace if failure Water pump failure...

Страница 9: ...g Check and adjust the mode setting Compressor Check and replace if the compressor the over load protector or wiring is broken Electric heater failure Check and replace if the heater is damaged Over h...

Страница 10: ...Andi Co Australia Pty Ltd Service manual for K1 portable Series 9 3 2 FOR COOLING AND HEATING MODELS MPK1 12ER QB6 MPK1 14ER QB6...

Страница 11: ...Andi Co Australia Pty Ltd Service manual for K1 portable Series 10 3 3 ELECTRICAL CONTROL SCHEME...

Страница 12: ...Andi Co Australia Pty Ltd Service manual for K1 portable Series 11 3 4 MAIN CONTROL BOARD SCHEME...

Страница 13: ...Andi Co Australia Pty Ltd Service manual for K1 portable Series 12 3 5 DISPLAY BOARD SCHEME...

Страница 14: ...d disconnect the Air pipe from rear of the unit Move the unit to a replace where water can be poured Remove the rubber plug from back of the unit and drainage the water in from the unit Remove the wat...

Страница 15: ...ly just push the clasp and release the assembly Now it is easy to replace the display board Take care to release the connector which connected to the display board 4 4 To disassemble the front panel R...

Страница 16: ...attention to the wires in the enclosure 1 2 3 4 5 6 7 8 9 10 1 Terminate to display board 2 Terminate to condenser fan motor 3 Out put of transformer 4 Terminate to evaporator fan motor 5 Terminate to...

Страница 17: ...ng the air out frame Lift the frame up then pull the frame forward Remove the screws fixing the fan shell box Remove the fan motor fan scroll and blower wheel from the unit Take care to the wires for...

Страница 18: ...he screws fixing the evaporator Remove the screws fixing the condenser fan motor bracket Then remove the bracket with condenser fan motor and blower wheel from the unit 4 9 To repair the refrigerant s...

Страница 19: ...e cover Then remove the condenser fan scroll Now it is easy to repair the refrigerant system 4 10 To repair the water disposal system or replace the water depth switch or the pump Remove the screws fi...

Страница 20: ...screw fixing the water switch which controls the water in tank Press the clamp fixing the water switches which control the water in the chassis Press downward here Then remove the screws fixing the s...

Отзывы: