Section 2 - Introduction

2.1 DESCRIPTION

The HM is a volumetric turbine flowmeter.  As liquid flows through the meter, it causes the rotor to spin.  An 

external non-contact pick-up probe counts each passing vane of the rotor as it spins.  Each revolution of the 

rotor equates to an exact volume of liquid.  This digital signal may feed instrumentation such as controllers or 

digital indicators.  The sealed probe and stainless construction meet the demands of damp or wet applications, 

and may be directly washed down during normal cleanup.  Units are shipped pre-calibrated from the factory 

with a pulse per gallon value identified on the body.

Section 3 - Installation

3.1 LOCATION

The HM  turbine series flowmeter provides accurate measuring results when installed in either a vertical or 

horizontal pipe section.  Select a location where the meter body will be completely filled with product (see 

figure 3.2). There must be a rise of pipeline elevation from the outlet side of the meter.  Avoid the presence of 

air, either bulk or entrained, from entering the product as it passes through the flow tube.
In a vertical pipe section, install the meter body in the upward direction of flow.  In a horizontal pipe section, 

install the meter body at the lowest possible point of the piping system.
Be sure the arrow on the body of the meter points in the direction of flow.
Install the meter with a minimum of 10 pipe diameters of straight tubing upstream  and 5 pipe diameters of 

straight tubing downstream.  Under normal conditions the meter should be installed in a positive pressure 

location.

When installing the transducer in the meter body, hand tighten the transducer until it bottoms out.  

DO NOT 

USE A WRENCH

, as you may damage the transducer.  Secure the position of the transducer with the hex jam 

nut.  

FIGURE 3.2 INSTALLATION

Guidelines

Installation Illustrations

A

Install in a horizontal pipe section 

at a low point before a rising 

pipeline to ensure meter body 

remains full.

B

Install in a vertical pipe section 

with an upward direction of flow to 

ensure meter body remains full.

C

Do not install in a horizontal pipe 

section located at the highest point 

of pipeline. This location allows 

air to accumulate in the flow tube 

which causes measuring errors.

D

Do not install in a vertical pipe sec-

tion with a downward direction of 

flow. This location allows air to ac

-

cumulate in the meter body which 

causes measuring errors.

A

B

C

D

10 x PIPE
DIAMETER
MINIMUM

5 x PIPE
DIAMETER
MINIMUM

5 x PIPE
DIAMETER
MINIMUM

10 x PIPE
DIAMETER
MINIMUM

Содержание HM075

Страница 1: ...00 833 0081 Fax 518 922 8997 www anderson negele com Instruction Manual Instrument Model Number _____________________________ Instrument Serial Number _________________________________ Form Number AIC2051 6 04 Effective October 2011 Supersedes July 2011 HM TURBINE FLOWMETER ...

Страница 2: ...n 3 Installation 5 3 1 Location 5 3 2 Installation Illustration 5 Section 4 Electrical Wiring 6 4 1 Signal Probe Wiring 6 4 2 Wiring Diagram 6 Section 5 Calibration 7 5 1 K Factor 7 Section 6 Maintenance 8 6 1 Disassembly 8 6 2 HM Materials List 8 6 3 Assembly 9 6 4 Rotor Wear 9 6 5 Housing Wear 9 Section 7 Troubleshooting 10 Section 8 Warranty and Return Statement 11 ...

Страница 3: ...ZE SANITARY CLAMP CONNECTION FLOW RANGE HM075 3 4 1 5 17 GPM 18 5 65 LPM HM100 1 1 7 70 GPM 26 5 265 LPM HM150 1 1 2 1 1 2 13 130 GPM 49 492 LPM HM200 2 2 25 250 GPM 94 946 LPM Accuracy 0 50 of rate Over Entire Flow Range Repeatability 0 10 Maximum Product Temperature 300 F 149 C Maximum Inlet Pressure 150 psi 10 3 Bar Maximum Product Viscosity 100 cps MATERIAL CONSTRUCTION Housing 316L Stainless ...

Страница 4: ...E DIMENSIONS MODEL DIM A DIM B FITTING HM075 HM100 3 25 82 6mm 5 88 149 4mm 1 T C HM150 3 63 92 2mm 6 13 155 7mm 1 1 2 T C HM200 3 88 98 6mm 8 63 219 2mm 2 T C A B 6 REF PICK UP PROBE CONNECTION TO EXTENSION CABLE FLOW 3 4 NPT ...

Страница 5: ...ection of flow In a horizontal pipe section install the meter body at the lowest possible point of the piping system Be sure the arrow on the body of the meter points in the direction of flow Install the meter with a minimum of 10 pipe diameters of straight tubing upstream and 5 pipe diameters of straight tubing downstream Under normal conditions the meter should be installed in a positive pressur...

Страница 6: ... HT750000 PICK UP PROBE SPECIFICATIONS SIGNAL OUT OPERATIONAL FREQUENCY RANGE OUTPUT VOLTAGE SINE WAVE 0 1000Hz 18 2 6 V P P HT750000 LENGTH APPROX 12 WHEN THREADED INTO HM SERIES FLOWMETER HMP SERIES TURBINE FLOWMETER V OUTPUT WIRING Hz SIGNAL OUTPUT NO POLARITY ANDERSON INSTRUMENT CO INC RED BLK COM WH SIG PART NUMBER HTS1000 MALE PIN 3 MALE PIN 2 WHITE WIRE RED WIRE FEMALE SOCKET 1 BLACK WIRE R...

Страница 7: ...s identifies the amount of pulses the meter will output per a fixed volume that passes through it In the case of Anderson flow products a gallon is the volume This value is labeled on the meter body as a P G pulses per gallon which is also know as a K Factor Pulsed output values are normally entered into digital converter as a divider value K Factor or as a multiplier value known as a Scale Factor...

Страница 8: ... abrasive products that would deteriorate the rotor bearing Figure 6 4 Housing damage occurs from a worn rotor The ID of the rotor can wear to a point where the OD will contact the housing This condition will immediately diminish the performance of the flowmeter Prolonged operation under these circumstances can permanently damage the meter housing Figure 6 5 FIGURE 6 2 HM MATERIALS LIST FLOW 8 9 1...

Страница 9: ...ure 6 2 DO NOT FORCE THE PIECES TOGETHER Be sure the gasket between the meter housings is in the groove of the body connection area Secure the housing clamp and reinstall in the process line FIGURE 6 4 ROTOR WEAR REPLACE ROTOR CHANGE ROTOR TO REVERSE POSITION OR REPLACE ROTOR NEW ROTOR NEW ROTOR ROTOR WITH WORN BEARING ROTOR WITH WORN BEARING FIGURE 6 5 HOUSING WEAR ROTOR WEAR ...

Страница 10: ...black white signal wires for 975Ω Poor accuracy repeatability Air in system Process flow rate out of meter flow range Obstructed Rotor Probe not seated Poor meter installation Poor system hydraulics Incorrect scale factor Electrical noise Changing product characteristics density and or viscosity Inaccurate proving standard Operating error poor testing method Rotor wear Damaged housing Add air elim...

Страница 11: ...the cost or expense of repair or replacement as described above Products must be installed and maintained in accordance with Anderson instructions Users are responsible for the suitability of the products to their application There is no warranty against damage resulting from corrosion misapplication improper specifications or other operating condition beyond our control Claims against carriers fo...

Страница 12: ... 518 922 8997 ANDERSON INSTRUMENT CO LP 400 BRITANNIA RD EAST UNIT 1 MISSISSAUGA ONTARIO L4Z 1X9 CANADA 905 603 4358 FAX 905 568 1652 NEGELE MESSTECHNIK GmbH A Division of Anderson RAIFFEISENWEG 7 D 87743 EGG A D GÜNZ GERMANY 49 0 8333 9204 0 FAX 49 0 8333 9204 49 www anderson negele com ...

Отзывы: