background image

P

AGE

  11

Section 8 - Warranty and Return Statement

These products are sold by The Anderson Instrument Company  (Anderson) under the warranties set forth in 

the following paragraphs.  Such warranties are extended only with respect to a purchase of these products, as 

new merchandise, directly from Anderson or from an Anderson distributor, representative or reseller, and are 

extended only to the first buyer thereof who purchases them other than for the purpose of resale.

Warranty

These products are warranted to be free from functional defects in materials and workmanship at the time the 

products leave the Anderson factory and to conform at that time to the specifications set forth in the relevant 

Anderson instruction manual or manuals, sheet or sheets, for such products for a period of one year.

THERE ARE NO EXPRESSED OR IMPLIED WARRANTIES WHICH EXTEND BEYOND THE 

WARRANTIES HEREIN AND ABOVE SET FORTH.  ANDERSON MAKES NO WARRANTY OF 

MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO THE 
PRODUCTS.

Limitations

Anderson shall not be liable for any incidental damages, consequential damages, special damages, or any 

other damages, costs or expenses excepting only the cost or expense of repair or replacement as described 

above.

Products must be installed and maintained in accordance with Anderson instructions.  Users are responsible 

for the suitability of the products to their application.  There is no warranty against damage resulting from 

corrosion, misapplication, improper specifications or other operating condition beyond our control.  Claims 

against carriers for damage in transit must be filed by the buyer.

This warranty is void if the purchaser uses non-factory approved replacement parts and supplies or if the 

purchaser attempts to repair the product themselves or through a third party without Anderson  authorization.

Returns

Anderson’s sole and exclusive obligation and buyer’s sole and exclusive remedy under the above warranty 

is limited to repairing or replacing (at Anderson’s option), free of charge, the products which are reported in 

writing to Anderson at its main office indicated below.

Anderson is to be advised of return requests during normal business hours and such returns are to include 

a statement of the observed deficiency.  The buyer shall pre-pay shipping charges for products returned and 

Anderson or its representative shall pay for the return of the products to the buyer.

Approved returns should be sent to: 

ANDERSON INSTRUMENT COMPANY INC.

 

156 AURIESVILLE ROAD

 

FULTONVILLE, NY 12072  USA

 

 

ATT: REPAIR DEPARTMENT

Содержание HM075

Страница 1: ...00 833 0081 Fax 518 922 8997 www anderson negele com Instruction Manual Instrument Model Number _____________________________ Instrument Serial Number _________________________________ Form Number AIC2051 6 04 Effective October 2011 Supersedes July 2011 HM TURBINE FLOWMETER ...

Страница 2: ...n 3 Installation 5 3 1 Location 5 3 2 Installation Illustration 5 Section 4 Electrical Wiring 6 4 1 Signal Probe Wiring 6 4 2 Wiring Diagram 6 Section 5 Calibration 7 5 1 K Factor 7 Section 6 Maintenance 8 6 1 Disassembly 8 6 2 HM Materials List 8 6 3 Assembly 9 6 4 Rotor Wear 9 6 5 Housing Wear 9 Section 7 Troubleshooting 10 Section 8 Warranty and Return Statement 11 ...

Страница 3: ...ZE SANITARY CLAMP CONNECTION FLOW RANGE HM075 3 4 1 5 17 GPM 18 5 65 LPM HM100 1 1 7 70 GPM 26 5 265 LPM HM150 1 1 2 1 1 2 13 130 GPM 49 492 LPM HM200 2 2 25 250 GPM 94 946 LPM Accuracy 0 50 of rate Over Entire Flow Range Repeatability 0 10 Maximum Product Temperature 300 F 149 C Maximum Inlet Pressure 150 psi 10 3 Bar Maximum Product Viscosity 100 cps MATERIAL CONSTRUCTION Housing 316L Stainless ...

Страница 4: ...E DIMENSIONS MODEL DIM A DIM B FITTING HM075 HM100 3 25 82 6mm 5 88 149 4mm 1 T C HM150 3 63 92 2mm 6 13 155 7mm 1 1 2 T C HM200 3 88 98 6mm 8 63 219 2mm 2 T C A B 6 REF PICK UP PROBE CONNECTION TO EXTENSION CABLE FLOW 3 4 NPT ...

Страница 5: ...ection of flow In a horizontal pipe section install the meter body at the lowest possible point of the piping system Be sure the arrow on the body of the meter points in the direction of flow Install the meter with a minimum of 10 pipe diameters of straight tubing upstream and 5 pipe diameters of straight tubing downstream Under normal conditions the meter should be installed in a positive pressur...

Страница 6: ... HT750000 PICK UP PROBE SPECIFICATIONS SIGNAL OUT OPERATIONAL FREQUENCY RANGE OUTPUT VOLTAGE SINE WAVE 0 1000Hz 18 2 6 V P P HT750000 LENGTH APPROX 12 WHEN THREADED INTO HM SERIES FLOWMETER HMP SERIES TURBINE FLOWMETER V OUTPUT WIRING Hz SIGNAL OUTPUT NO POLARITY ANDERSON INSTRUMENT CO INC RED BLK COM WH SIG PART NUMBER HTS1000 MALE PIN 3 MALE PIN 2 WHITE WIRE RED WIRE FEMALE SOCKET 1 BLACK WIRE R...

Страница 7: ...s identifies the amount of pulses the meter will output per a fixed volume that passes through it In the case of Anderson flow products a gallon is the volume This value is labeled on the meter body as a P G pulses per gallon which is also know as a K Factor Pulsed output values are normally entered into digital converter as a divider value K Factor or as a multiplier value known as a Scale Factor...

Страница 8: ... abrasive products that would deteriorate the rotor bearing Figure 6 4 Housing damage occurs from a worn rotor The ID of the rotor can wear to a point where the OD will contact the housing This condition will immediately diminish the performance of the flowmeter Prolonged operation under these circumstances can permanently damage the meter housing Figure 6 5 FIGURE 6 2 HM MATERIALS LIST FLOW 8 9 1...

Страница 9: ...ure 6 2 DO NOT FORCE THE PIECES TOGETHER Be sure the gasket between the meter housings is in the groove of the body connection area Secure the housing clamp and reinstall in the process line FIGURE 6 4 ROTOR WEAR REPLACE ROTOR CHANGE ROTOR TO REVERSE POSITION OR REPLACE ROTOR NEW ROTOR NEW ROTOR ROTOR WITH WORN BEARING ROTOR WITH WORN BEARING FIGURE 6 5 HOUSING WEAR ROTOR WEAR ...

Страница 10: ...black white signal wires for 975Ω Poor accuracy repeatability Air in system Process flow rate out of meter flow range Obstructed Rotor Probe not seated Poor meter installation Poor system hydraulics Incorrect scale factor Electrical noise Changing product characteristics density and or viscosity Inaccurate proving standard Operating error poor testing method Rotor wear Damaged housing Add air elim...

Страница 11: ...the cost or expense of repair or replacement as described above Products must be installed and maintained in accordance with Anderson instructions Users are responsible for the suitability of the products to their application There is no warranty against damage resulting from corrosion misapplication improper specifications or other operating condition beyond our control Claims against carriers fo...

Страница 12: ... 518 922 8997 ANDERSON INSTRUMENT CO LP 400 BRITANNIA RD EAST UNIT 1 MISSISSAUGA ONTARIO L4Z 1X9 CANADA 905 603 4358 FAX 905 568 1652 NEGELE MESSTECHNIK GmbH A Division of Anderson RAIFFEISENWEG 7 D 87743 EGG A D GÜNZ GERMANY 49 0 8333 9204 0 FAX 49 0 8333 9204 49 www anderson negele com ...