background image

 

User's manual 

Guangzhou Andea Electronics Technology Co., Ltd.                             

8/18 

http://www.gzandea.com     

         

 

Select the appropriate communication method according to the actual interface 

type of the device: Since the communication interface of the device is a USB interface, 

select "USB Communication" in [Communication Interface] under [Search 

Parameters]. 

After the communication interface is set up, click the [Search] button to find the 

device. After the device is found, the device information will be automatically 

displayed in the "Discovered Devices" list as follows: 

 

 

User's manual 

Guangzhou Andea Electronics Technology Co., Ltd.                             

17/18 

http://www.gzandea.com     

         

 

 

Note

Step 1: In the software main interface, select the menu "Single Tag Test"; 

Step 2: in the "Single Tag Test" interface, select the type of tag to be operated; 

Step 3: mode: none address, address. 

         1, For a single tag, select the "none address" mode. 

         2, For multiple tags, select the "address" mode. 

Step 4: Click the "Inventory" button to display the uid list in UID drop-down 

box. 

Step 5: 1, For a single tag: click the "Connect" button; 

            2, For multiple tags: in UID drop-down box, select the tags required to 

be operated, and then click the "Connect" button; 

After the above steps, you can read and write tags, as shown below: 

 

Содержание TPAD20 M

Страница 1: ...this manual and properly keep it for future reference As our products continue improving they may be changed without advanced notice The contents of this manual have been carefully checked For any pr...

Страница 2: ...Communication connection 5 3 2 Power connection 6 4 LED instruction 6 5 Instructions for configuration tools 7 5 1 Description of configuration parameters 9 5 1 1 Configuration Parameter Description 1...

Страница 3: ...and check in environment book sorter librarian workstation production lines etc 1 2 Product features Working frequency is 13 56Mhz Support ISO15693 ISO18000 3M1 standard RF power 0 25 1 5W adjustable...

Страница 4: ...rt the USB powered mode Maximum power consumption 3 5W Anti metal design Yes Shell material PCB metal plate Dimensions 379 5x290x20 7mm Dimensions are approximate For specific dimension please refer t...

Страница 5: ...that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off a...

Страница 6: ...Interface description 2 4 Communication interface Communication interface of the device adopts the USB interface as shown below User s manual Guangzhou Andea Electronics Technology Co Ltd 21 18 http w...

Страница 7: ...urce one by one At the same time observe changes of the interface waveform in order to determine the interference source 7 Technical Support Download link for development data and testing Address 1 ht...

Страница 8: ...power supply should be connected Power connection 4 LED instruction User s manual Guangzhou Andea Electronics Technology Co Ltd 19 18 http www gzandea com function of the testing software Click the No...

Страница 9: ...nges etc When these problems occur there may be electromagnetic interference in the environment rather than the machine performance issue Interference source can be judged and investigated by the nois...

Страница 10: ...overed Devices list as follows User s manual Guangzhou Andea Electronics Technology Co Ltd 17 18 http www gzandea com Note Step 1 In the software main interface select the menu Single Tag Test Step 2...

Страница 11: ...he following figure and for tag operation testing User s manual Guangzhou Andea Electronics Technology Co Ltd 9 18 http www gzandea com As shown above Step click the Start button to enter the main int...

Страница 12: ...Set the vendor code used when the tag type cannot be identified 1 Tag it 2 NXP Tag s ID Set the tag code used when the tag type cannot be identified Note The above configuration is a common configura...

Страница 13: ...arameters of the scan mode Data block start address Set the start address of the data block to be scanned Number of blocks scanned Set the number of blocks to be scanned Scan the serial number of the...

Страница 14: ...Anti collision parameter configuration instructions Fast Mode Check to open the fast mode Note this function is available to V1 1 4 13 and above of R TOOL configuration software Slot Set the reader s...