![AND Weighing Indicator AD-4401 Скачать руководство пользователя страница 79](http://html1.mh-extra.com/html/and/weighing-indicator-ad-4401/weighing-indicator-ad-4401_instruction-manual_2941326079.webp)
77
CHAPTER 11 SETTING LISTS
Use the settings list as a quick reference for maintenance of your AD-4401. When consulting with your A & D
representative, let them know the user set values.
11-1 GENERAL FUNCTIONS
BASIC FUNCTIONS
Setting
FNCF- Name
User’s
Default
Parameter Description
0 Not
disable
01
Key switch
disable
00000000
00000000
to
11111111
1 Disables
Each bit corresponding to the
relevant key
0 None
1
Print command for manual
print
2 Hold
3 *
Batch
Start
4
* Emergency stop
5 Clear
to
zero
6 Clear
tare
7 Clear
accumulation
02
Capabilities of
[F] Key
0
8
lb-kg conv.(USA ver.)
* : Denotes exclusive for
Normal batching mode.
1 20
times/sec
2 10
times/sec
03
Display
Rewrite Rate
1
3 5
times/sec.
0 None
1
Gross
2 Net
3
Tare
4
Final value (Target weight)
5
Accumulated weight
04
Display
Content of
Subdisplay
Section
0
6 Accumulated
count
Paste the accessory label to
the front panel in compliance
with the display content.
0 None
1 *
discharging
05
" "
status display
Capability
0
2 Zero
tracking
"Discharging" is exclusively
intended for normal batching
(built-in automatic program
mode).
Series connection of
two digital filters.
Value of each digit
and cutoff frequency
0: None
1: 11.0 Hz
2: 8.0 Hz
3: 5.6 Hz
4: 4.0 Hz
5: 2.8 Hz
6: 2.0 Hz
7: 1.4 Hz
8: 1.0 Hz
06 Digital
Filter.
48
00
to
79
9: 0.7 Hz
The digital filter is designed to
suppress dispersion of a load
cell output signal. Two of them are
connected in series as shown below.
Low frequency components which
cannot be covered only by setting of
the digital filters can be dealt with by
equivalently lowering the cutoff
frequency of the digital filters at
FNCF-07.
07
Sampling
frequency
dividing ratio.
1
1
to
10
Lower the cutoff frequency of the digital filters equivalently by
reducing the specified sampling times to one.
1 Normal
hold
08
Hold
operation
1
2 Peak
hold
During peak hold, the positive peak of
the weight value is held.
0 No
09
Comparison
stop at hold
0
1 Yes
In case of sequential batching, do not