7.3.3.
7.3.3.
7.3.3.
7.3.3.
CCCCompensation
ompensation
ompensation
ompensation SSSSequence
equence
equence
equence
The compensation sequence is used to make up (add) the material automatically,
when the result of the current batch weighing is under weight.
Concerning Parameters of the Function
Storing a maximum repeat count of the compensation sequence.
[
5q f-18
]
If number is zero, this sequence is canceled. When the result is
under weight after the sequence, An error
SQ.ERR 2
is displayed.
[Function] - [Function setting] - [Sequence] - [Control] - [Maximum number
of compensation]
Setting the time to open the dribble gate.
Set the time for each material code.
[Function] - [Function setting] - [MatEDIT] - [Edit] - [SF flow open timer]
Setting the time to close the dribble gate.
Set the time for each material code.
When the displayed value is stable and under weight, the
compensation is repeated. Take a longer time closing the gate, if it
does not use a stable signal.
[Function] - [Function setting] - [MatEDIT] - [Edit.] - [SF flow close timer]
Removing the nozzle at this sequence, when the nozzle operation is used.
[
5q f-12
] [
2
]
Nozzle contact stop sequence
Factory setting is "not used". When it is necessary to shift up the
nozzle to reduce a weighing error, use this parameter of [
5q f-12
].
[Function] - [Function setting] - [Sequence] - [Control] - [Nozzle control]