AD-4402-20
Page 17
4.3.5.
4.3.5.
4.3.5.
4.3.5.
Reading Commands
Reading Commands
Reading Commands
Reading Commands
1 Set a material code (No. 33) or recipe code (No. 57) in the
storing command
(RWw000E).
2 Turn on the
Read/Write selection
(RY0003).
3 Set the kind of data to the
command code
(RWw000E)
4 The result is output to the
reply register
(RWr000C to 000D).
4.3.6.
4.3.6.
4.3.6.
4.3.6.
Storing Commands
Storing Commands
Storing Commands
Storing Commands
1 Set a material code (No. 33) or recipe code (No. 57) in the
storing command
(RWw000E).
2 Turn off the
Read/Write selection
(RY0003).
3
Set the kind of data to the
command code
(RWw000E)
4 Set data to the
command register
(RWw000C, RWw000D).
Request flag to store setpoint (RY0000)
Setpoints (RWw0000 to RWw000B)
Reply flag to store setpoints (RX0000)
Step 3
Step 4
Command request flag (RY0002)
Command data reply (RWr000C, RWr000D)
Read/Write reply (RX0003)
Read/Write selection (RY0003)
Command code (RWw000E)
Command code reply (RWr000E)
Command reply flag (RX0002)
Step 2
Step 2
Command request flag (RY0002)
Command data (RWw000C, RWw000D)
Read/Write reply (RX0003)
Read/Write selection (RY0003)
Command code (RWw000E)
Command code reply (RWr000E)
Command reply flag (RX0002)
Содержание CC-Link Interface AD-4402-OP-20
Страница 1: ...ふ Interface WM PD4000299A ...
Страница 22: ...Page 20 AD 4402 20 MEMO ...