Page 4
AD-4402-20
OP-20
CC-Link
DB
SLD
FG
RUN
ERR
SD
RD
X1
3.
3.
3.
3.
Panel
Panel
Panel
Panel
Station number switch
Station number range: 1 to 61.
Set the CC-link station number (address number).
This option occupies four station numbers.
Example: When the station number "1" is set, "1", "2", "3" and "4" are occupied.
Avoid any overlapped station numbers.
Baud rate switch
Switch No.
Baud rate
0
156 kbps
1
625 kbps
2
2.5 Mbps
3
5 Mbps
4
10 Mbps
Status LED
Name
Illuminated
Off
Blinking
RUN
Normal
Resetting
No signal
SD
Transmitting
RD
Receiving
ERR
Parameter error
CRC error
Station trouble
Normal
Changing
parameter
Station number switch
(Address number switch)
Status LED
Connector
Connector
F5210A-5P
Baud rate switch
Shield terminal
Frame ground terminal
Signal terminals
Signal ground terminal