09 - DEVICES COMPATIBILITY
RFID “ISO” / “CLAMSELL” card
RFID keychain
10 - LOCK ACTIVATION, MAGNETIC LOCK OR INDUCTIVE LOAD CARES
In cases of inductive load activation, as locks or magnetic lock, turnstile’s bobbins or collector turnstile, besides others, to avoid the return of electric current
during the bobbins shutdown, use the indicated components according the instructions below.
DIODE FILTER CONNECTION SCHEME (Level 1 protection - Applies to direct current “DC”)
CAPACITOR (Level 1 protection - Applies to alternate current “A C”)
DIODE + CAPACITOR (Level 2 protection - Applies to direct current “DC”)
LINE FILTER FOR LOCKS (Level 3 protection - Applies to direct or alternate current. Filters and rectifies the “AC” current to “DC”)
11 - FRONTAL LED AND INTERNAL BUZZER SIGNALING
Bringing a card or keychain close to the LN-104C EMF reader, will occur an auxiliary signaling by the frontal LED, and an audible alert.
NOT COMPATIBLE CARD OR KEYCHAIN:
The reader emits a warning signal, at the registration moment, 5 fast beeps and 5 synchronized LED blinks.
ACTIVATION WITH COMPATIBLE CARD OR KEYCHAIN NOT REGISTERED:
The reader emits a warning signal with a unique beep and a unique
synchronized LED blink.
VALID ACTIVATION WITH A REGISTERED CARD OR KEYCHAIN:
The reader emits a warning signal with 3 sequential beeps and 3 synchronized LED
blinks, or 4 sequential beeps, and 4 synchronized LED blinks if the reader is working in the standalone mode.
Incompatible card
Valid activation (registered card)
Compatible card not registered
Signaling graphic by LED/Buzzer
SOLENOID
Solenoid power
DIODE 1N4004 OR 1N4007
CATHODE
ANODE
SOLENOID
Solenoid power
X2 0,1uF
275V
SUPPRESSOR CAPACITOR “X2” 0,1uF 275V
- NOTE: THERE IS NO POLARITY
SOLENOID
DIODE 1N4004 OR 1N4007
Solenoid power
SUPPRESSOR CAPACITOR “X2” 0,1uF 275V
CATHODE
ANODE
SOLENOID
FILTRO DE LINHA
PARA FECHADURAS
LINE FILTER FOR LOCKS
AC/DC
Solenoid power
ENGLISH