7
TROUBLE SHOOTING CHECKLIST
1. Use a voltmeter to measure the input voltage. The input should match the rating printed on
the unit.
2. Ensure that the battery is connected correctly: Red to Positive, Black to Negative.
3. Check the specifications of the load to see what power it consumes and test it from a
standard wall outlet.
4. Unplug all devices connected to the unit and turn it on.
5. Make a note of any LED’s that stay on.
6. Ensure that the Power Save mode is not activated.
7. If the unit cycles on and off, check and see if the standby light comes on when the unit is
off. If so, the Power Save mode is set too close to the recovery (40 watts) load. Adjust the
Power Save mode in accordance with the previous instructions.
8. Disconnect the input power and remove the cover. Check the automotive type fuses (ATC)
which are visible at the top of the circuit board. If any are blown, replace all of them with the
correct value shown in the specifications and on the label.
DEFECTS OR DAMAGE
If after checking all of the above and the problem persists, you may assume the unit is defective
or damaged and it must be returned for repair.