5
OUTPUT CONNECTIONS
One standard AC receptacle is provided for connection of up to two devices.
Ensure that the total average load does not exceed the continuous current rating of the unit.
CAUTION:
Do not apply AC voltage to the outlet. Damage caused by this action
will not be covered under warranty.
DISCONNECTION
If you disconnect the unit to remove it for service or storage, turn the power switch on for at
least one minute after it has been disconnected to discharge the storage capacitors.
OPERATION
Turn the switch on the front of the unit on to energize the outputs.
The switch will glow to indicate the presence of AC power at the receptacles.
POWER SAVE
The Power Save feature allows the user to set the level at which the unit goes into the Power
Save mode. The Power Save mode adjustment is accessed on the front of the unit. A small
flat bladed instrument screwdriver is used to make the adjustment.
Turning the potentiometer fully counter clockwise forces the Power Save mode to off. This
means that the inverter will continue to output 120VAC even if there is no devices connected to
it. Turning the potentiometer clockwise will set the level at which the Power Save mode will
operate.
The unit is internally set to come back on at 40 watts. This means that once the unit has gone
into the Power Save mode, the load must be at least 40 watts for the unit to come back on.
When the standby light on the front of the inverter is lit, the unit is in the Power Save mode.