Analytic Systems BCA610 Series Скачать руководство пользователя страница 14

Limited Warranty

1. The equipment manufactured by Analytic Systems Ware (1993) Ltd. (the “Warrantor”) is warranted to be free 

from defects in workmanship and materials under normal use and service.

2. This warranty is in effect for:

a.

3 Years from date of purchase by the end user for standard products offered in our catalog.

b.

2 Years from date of manufacture for non-standard or OEM products

c.  1 Year from date of manufacture for encapsulated products.

3. Analytic Systems will determine eligibility for warranty from the date of purchase shown on the warranty card 

when returned within 30 days, or

a.

The date of shipment by Analytic Systems, or

b.

The date of manufacture coded in the serial number, or 

c.  From a copy of the original purchase receipt showing the date of purchase by the user.

4. In case any part of the equipment proves to be defective, the Purchaser should do the following:

a.

Prepare a written statement of the nature of the defect to the best of the Purchasers knowledge, and 

include the date of purchase, the place of purchase, and the Purchasers name, address and telephone 

number.

b.

Call Analytic Systems at 800-668-3884 or 604-946-9981 and request a return material authorization 

number (RMA).

c.  Return the defective part or unit along with the statement at the Purchasers expense to the Warrantor; 

Analytic Systems Ware (1993) Ltd., 8128 River Way, Delta, B.C., V4G 1K5, Canada.

5. If upon the Warrantor’s examination the defect proves to be the result of defective material or workmanship, 

the equipment will be repaired or replaced at the Warrantor’s option without charge, and returned to the 

Purchaser at the Warrantor’s expense by the most economical means. Requests for a different method of return 

or special handling will incur additional charges and are the responsibility of the Purchaser.

6. Analytic Systems reserves the right to void the warranty if:

a.

Labels, identification marks or serial numbers are removed or altered in any way.

b.

Our invoice is unpaid.

c.  The defect is the result of misuse, neglect, improper installation, environmental conditions,  non-autho-

rized repair, alteration or accident.

7. No refund of the purchase price will be granted to the Purchaser, unless the Warrantor is unable to remedy the 

defect after having a reasonable number of opportunities to do so.

8. Only the Warrantor shall perform warranty service. Any attempt to remedy the defect by anyone else shall 

render this warranty void.

9. There shall be no warranty for defects or damages caused by faulty installation or hook-up, abuse or misuse of 

the equipment including exposure to excessive heat, salt or fresh water spray, or water immersion except for 

equipment specifically stated to be waterproof.

10. No other express warranty is hereby given and there are no warranties that extend beyond those described 

herein. This warranty is expressly in lieu of any other expressed or implied warranties, including any implied 

warranty of merchantability, fitness for the ordinary purposes for which such goods are used, or fitness for a 

particular purpose, or any other obligations on the part of the Warrantor or its employees and representatives.

11. There shall be no responsibility or liability whatsoever on the part of the Warrantor or its employees and rep-

resentatives for injury to any person or persons, or damage to property, or loss of income or profit, or any other 

consequential or resulting damage which may be claimed to have been incurred through the use or sale of the 

equipment, including any possible failure of malfunction of the equipment, or part thereof.

12. The Warrantor assumes no liability for incidental or consequential damages of any kind

Содержание BCA610 Series

Страница 1: ...INSTALLATION OPERATION MANUAL BCA610 SERIES AC SOURCE BATTERY CHARGER ...

Страница 2: ... to drip on the battery charger BATTERY SAFETY 1 WARNING RISK OF EXPLOSIVE GASES i WORKING IN VICINITY OF A LEAD ACID BATTERY IS DANGEROUS BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION FOR THIS REASON IT IS OF UTMOST IMPORTANCE THAT EACH TIME BEFORE SERVICING EQUIPMENT IN THE VICINITY OF THE BATTERY YOU READ THIS USER GUIDE AND FOLLOW THE INSTRUCTIONS EXACTLY ii To reduce risk...

Страница 3: ...r connection can result in the risk of electric shock vii NEVER smoke or allow a spark or flame in the vicinity of a battery viii Be extra cautious to reduce risk of dropping a metal tool onto battery It might spark or short circuit the battery or other electrical part that may cause a fire or explosion ix Remove personal metal items such as rings bracelets necklaces and watches when working with ...

Страница 4: ...ank With the output voltage adjust and user selectable charging profiles you have optimal control in how you charge your batteries Additionally voltage temperature compensation protects your expensive battery banks from overly harsh charging prolonging their lifespan Internally the recently updated single board design incorporates time tested switch mode technology for unmatched efficiency and ult...

Страница 5: ...for their recommendations Output Nominal Voltage 12 VDC 24 VDC 32 VDC 48 VDC Float Voltage 13 6 0 05 VDC 27 2 0 05 VDC 36 3 0 05 VDC 54 4 0 05 VDC Absorption Voltage 14 4 VDC VDC 28 8 VDC 38 4 VDC 57 6 VDC Charging Amps 40 A 22 A 16 5 A 11 A Absorption to Float 6 0 Amps 3 3 Amps 2 48 Amps 1 65 Amps Battery Size Amp Hours 160 240 88 132 66 99 44 66 Output Adjust 1 0 Volts Noise on Output 50 mV Outp...

Страница 6: ... to the BCA 610 See Specifications for the maximum input current and recommended fuses AC Input Connection The unit is equipped with a 5 foot long power cable terminating in either a North American outlet compatible NEMA 5 15 plug or European outlet compatible CEE 7 7 plug to serve as an AC Input Connection If you must extend the power cable be sure to use a 3 conductor grounded type extension cab...

Страница 7: ... not lose physical contact with the battery at any point in the charging cycle Pictured Analytic Systems Battery Temperature Sensor Connect the battery bank s to the terminals using an appropriate gauge of wire for the charg ing amps Ensure that the total average load connected to the batteries does not exceed the unit s charging amps See Specifications for this unit s charging amps This connectio...

Страница 8: ... the charging voltage 1 Disconnect the battery temperature sensor s from the unit if connected 2 Move the Power Switch to ON 3 Loosen the two screws and remove the cover plate on the top panel to access the output voltage adjust potentiometer 4 Using a small flat blade screwdriver rotate the potentiometer 5 The charging voltage can be adjusted over a range of 10 Rotate the potentiometer clock wise...

Страница 9: ...e battery without altering the charger s ability to keep the battery at optimal charge In three stage charging the battery is charged at a constant current until the battery voltage reaches the absorption voltage The battery is maintained at this voltage while the current diminishes Once the current drops to 10 of it s initial value the battery is then held at the float voltage Three stage chargin...

Страница 10: ... If it is working correctly remount the battery charger for better air circulation LOW INPUT The battery charger s input voltage is too low for normal operation Fix Check that the power source is properly rated for the battery charger Check that the input cables and connection are free of damage and corrosion If all of the above are in proper working order the cause is likely an internal component...

Страница 11: ...harge the capacitors then turn it off again Remove the eight screws holding on the cover Turn the unit upside down remove the cover and locate J22 It will be next to the relay as is shown in the above diagram Simply move the jumper to the desired position as is shown in the above diagram Replace the cover and re install the eight screws Reconnect the unit to the power and batter ies BATTERY TEMPER...

Страница 12: ...l cells are fully charged and to reduce the chance of sulfation of the battery During the Equalize cycle the cells which are fully charged will produce Hydrogen gas and the cells which are undercharged will be brought up to full charge An Equalize cycle should be done once every 2 3 months or whenever battery capacity appears to be diminished The Equalize Option also includes a battery temperature...

Страница 13: ...ure sensor may be installed in many different ways so long as the sensor stays in contact with the battery The preferred method is as follows The batteries to be charged will be placed on a platform made of wood Prior to placing the batteries on the wooden platform a cavity is hollowed out such that the sensor will fit inside the cavity and be flush with the battery Place the sensor inside the cav...

Страница 14: ...ng will incur additional charges and are the responsibility of the Purchaser 6 Analytic Systems reserves the right to void the warranty if a Labels identification marks or serial numbers are removed or altered in any way b Our invoice is unpaid c The defect is the result of misuse neglect improper installation environmental conditions non autho rized repair alteration or accident 7 No refund of th...