9) REMOTE CONTROL RS-232 (continued)
9-2) HOST / SMART SCALER™ COMMUNICATION (continued)
d
OUTPUT COMMANDS :
•
o command
is used to select the Output Sync. type.
DECIMAL VALUE
SELECTION
(OUTPUT SYNC TYPE)
RESPONSE
0
SEPARATE H & V SYNC.
OSIG0
1
COMPOSITE SYNC.
OSIG1
•
O command
is used to select the output format.
Use the following table when the u command (Output Frame Rate) is set on Video In Rate (SSYNC3).
DECIMAL VALUE
SELECTION (OUTPUT FORMAT)
RESPONSE
0
VGA (640 x 480) at 50Hz or 59.94 Hz
OFMT0
1
PLASMA 42” (852 x 480) at 50Hz or 59.94 Hz
OFMT1
2
SVGA (800 x 600) at 50Hz or 59.94 Hz
OFMT2
4
XGA (1024 x 768) at 50Hz or 59.94 Hz
OFMT4
5
PLASMA 50” (1280 x 768) at 50Hz or 59.94 Hz
OFMT5
6
SXGA (1280 x 1024) at 50Hz or 59.94 Hz
OFMT6
14
HDTV 720 P (1280 x 720) at 50Hz or 59.94 Hz
OFMT14
15
QUAD 960 (1280 x 960) at 50Hz or 59.94 Hz
OFMT15
16
D-ILA (1365 x 1024) at 50Hz or 59.94 Hz
OFMT16
Use the following table when the u command (Output Frame Rate) is set on Internal Rate (SSYNC0).
DECIMAL VALUE
SELECTION (OUTPUT FORMAT)
RESPONSE
0
VGA (640 x 480) at 60Hz
OFMT0
1
PLASMA 42” (852 x 480) at 60Hz
OFMT1
2
SVGA (800 x 600) at 60Hz
OFMT2
3
MAC (640 x 480) at 66Hz
OFMT3
4
XGA (1024 x 768) at 60Hz
OFMT4
5
PLASMA 50” (1280 x 768) at 56Hz
OFMT5
6
SXGA (1280 x 1024) at 60Hz
OFMT6
7
VGA (640 x 480) at 75Hz
OFMT7
8
PLASMA 42” (852 x 480) at 72Hz
OFMT8
9
SVGA (800 x 600) at 75Hz
OFMT9
10
MAC 16” (832 x 624) at 75Hz
OFMT10
11
XGA (1024 x 768) at 75Hz
OFMT11
12
PLASMA 50” (1280 x 768) at 75Hz
OFMT12
13
SXGA (1280 x 1024) at 75Hz
OFMT13
•
u command
is used to select the Output Frame Rate.
DECIMAL VALUE
SELECTION
(OUTPUT RATE)
RESPONSE
0
INTERNAL RATE
SSYNC0
3
VIDEO IN RATE
SSYNC3