background image

 

HMC-T2000  User’s Manual                                                                                        HMC119983 Rev 1 
 

20

 

 

This window is displayed to show installation progress. 

 

 

 

Select Close. 

 

Содержание Hittite HMC-T2000

Страница 1: ...Analog Devices Welcomes Hittite Microwave Corporation NO CONTENT ON THE ATTACHED DOCUMENT HAS CHANGED www analog com www hittite com...

Страница 2: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 3: ...l Synthesized Signal Generator Hittite Model HMC T2000 Hittite Microwave Corporation 20 Alpha Road Chelmsford MA 01824 Tel 978 250 3343 Fax 978 250 3373 E mail sales hittite com Internet http www hitt...

Страница 4: ...n to a situation relating to the equipment set up operating or maintaining the equipment which if not observed could result in permanent damage to sensitive microwave devices or other electronic compn...

Страница 5: ...mage claims to the transporter Remove the documentation packet and any other separately supplied components before attempting to remove the SG unit from the shipping container It is highly recommended...

Страница 6: ...10MHz REF 10MHz TCXO POW ER REG USB REF OUT FRONT PANEL REF IN RF OUT 5VDC 15VDC 15VDC Figure 1 HMC T2000 Block Diagram 4 Installation of Equipment and Safety The bulleted guidelines shown below must...

Страница 7: ...etup and Operation Before the SG unit can be operated external coaxial cables equipment and instrumentation are required to be set up The instruction steps listed below must first be completed 1 Use a...

Страница 8: ...tor for the RF output See figure 2 for a view of the front panel The rear panel of the unit contains power On Off switch LCD contrast adjustment and the connectors for the External Reference Input Ref...

Страница 9: ...ment frequency with 1 MHz steps 2 Increment Decrement frequency with 10 MHz steps 3 Increment Decrement frequency with 100 MHz steps 4 Increment Decrement Output Power with 0 5 dBm steps Rotation of t...

Страница 10: ...s below for descriptions and illustrations of the power level indicators 5 2 3 2 Un calibrated Output Power The character is displayed next to the power level when the output power selected by the use...

Страница 11: ...he RF Output ON OFF status indicator See figure 6 below Figure 6 Minimum output power indicator 5 2 4 USB Connector The USB connector is located on the rear panel The USB interface is compliant with U...

Страница 12: ...specified in the datasheet on the Hittite website 5 2 5 2 External Reference The internal reference can be overridden by connecting an external reference to the BNC connector located on the rear pane...

Страница 13: ...5 non condensing Altitude Less than 3000 meters Table 4 Environmental Operating Conditions 5 4 Air Inlet The unit utilizes convection cooling Please ensure that the vent openings are not obstructed or...

Страница 14: ...y be accessed by pointing to the GUI and performing a Right Click with the mouse The functions available from this menu are ReMap Hardware Open Close Refresh and Disable Power Checks The top right pul...

Страница 15: ...r after the application has been started use the ReMap Hardware function to force the software to check for other synthesizers 5 5 4 Remote and Local Lockout The Remote and Local Lockout feature is en...

Страница 16: ...ication The Remote and Local Lockout checkbox must be selected in order for any of the sweep functions to be enabled 5 5 8 1 Single Sweep Start Continuous Sweep When the Single Sweep button is pressed...

Страница 17: ...provided to enter the value of the Dwell Time for each step in the sweep Valid values for this field are 0 001 secs to 3600 secs The value may be entered by typing the desired value or using the up a...

Страница 18: ...HMC T2000 User s Manual HMC119983 Rev 1 16 Select Next This window will be displayed during the install process This window shows status of the install...

Страница 19: ...HMC T2000 User s Manual HMC119983 Rev 1 17 The software is being installed Select Continue Anyway...

Страница 20: ...HMC T2000 User s Manual HMC119983 Rev 1 18 Select Finish Select Next...

Страница 21: ...983 Rev 1 19 Select the desired folder name and location and select whether you want anyone who uses this computer to be able to run the application The default folder location is recommended Select N...

Страница 22: ...HMC T2000 User s Manual HMC119983 Rev 1 20 This window is displayed to show installation progress Select Close...

Страница 23: ...HMC T2000 User s Manual HMC119983 Rev 1 21 Select OK Select the Program Group for installation Hittite is the recommended group...

Страница 24: ...ge the install directory if desired and then select the large button on the top left It is recommended that the installation is to the default directory This window indicates that the installer for th...

Страница 25: ...progress Select Close The installation of all software components is done 6 Maintenance The unit should be calibrated every 12 months The unit is provided with calibration software so that the user c...

Страница 26: ...ied with a Hittite software application to support the calibration of the unit s output power A picture of the GUI is shown in figure 8 The software will provide information related to the required eq...

Страница 27: ...amount of attenuation between at the output of the HMC T2000 and the Power Meter 6 Verify power is ON to the HMC T2000 and select Initialize T2000 and verify the following window appears 7 Select OK...

Страница 28: ...HMC T2000 User s Manual HMC119983 Rev 1 26 Select OK Select OK Select OK 10 Select Yes to begin calibration...

Страница 29: ...aim or cause of action that might otherwise arise out of the purchase and use of seller s products or service Seller shall not be liable for special or consequential damages of any nature with respect...

Отзывы: