Analog Devices Hittite HMC-T2000 Скачать руководство пользователя страница 15

 

HMC-T2000  User’s Manual                                                                                        HMC119983 Rev 1 
 

13

5.5.2.1 

Open 

The Open function is used to establish a connection to a specified synthesizer. A 
synthesizer is selected with the upper right hand pull-down menu. 

5.5.2.2 

Close 

The Close function is used to disconnect the currently selected synthesizer. A new 
synthesizer may then be selected with the upper right hand pull-down menu, and the 
Open function. 

5.5.2.3 

Refresh 

Once a synthesizer has been selected with the Open command, the Refresh function 
may be used to read the current status of the synthesizer. If the GUI checkbox for 
Remote and Local Lockout has not been checked, the Refresh function will read the 
current status of the unit as commanded via the synthesizer’s front panel. 

5.5.2.4 

Disable Power Checks 

Within the menu this function may be selected to disable software power level 
checking. 

5.5.3 

Synthesizer Selection Menu 

This is a pull-down menu at the top right hand side of the GUI. All synthesizers which have 
been detected by the software are displayed in this menu. If synthesizers are added to the 
computer after the application has been started, use the ReMap Hardware function to force 
the software to check for other synthesizers. 

5.5.4 

Remote and Local Lockout 

The Remote and Local Lockout feature is enabled by a checkbox available within the GUI. 
When the checkbox is selected, computer controlled operation via the USB is enabled. 
Front panel control of the unit is disabled. If this checkbox is not selected, the software 
application will not change any settings in the synthesizer. However in this state, if the 
Refresh button is depressed, the current Frequency and Power fields will be updated with 
the current settings within the synthesizer. 

5.5.5 

Frequency field  

When the Remote and Local Lockout checkbox is selected, the Frequency of the 
synthesizer may be controlled with the text-box. The desired frequency can be either typed 
into the provided text-box, or either the up and down arrows on the keyboard, or the GUI 
field may be used to increment or decrement the frequency by the amount indicated in the 
Step box. After a new frequency has been entered, the application attempts to set the 
synthesizer to the commanded frequency. If for any reason (Ex. outside the calibration 
range) the unit does not go to the commanded frequency, the field will be highlighted in 
yellow.  

Содержание Hittite HMC-T2000

Страница 1: ...Analog Devices Welcomes Hittite Microwave Corporation NO CONTENT ON THE ATTACHED DOCUMENT HAS CHANGED www analog com www hittite com...

Страница 2: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 3: ...l Synthesized Signal Generator Hittite Model HMC T2000 Hittite Microwave Corporation 20 Alpha Road Chelmsford MA 01824 Tel 978 250 3343 Fax 978 250 3373 E mail sales hittite com Internet http www hitt...

Страница 4: ...n to a situation relating to the equipment set up operating or maintaining the equipment which if not observed could result in permanent damage to sensitive microwave devices or other electronic compn...

Страница 5: ...mage claims to the transporter Remove the documentation packet and any other separately supplied components before attempting to remove the SG unit from the shipping container It is highly recommended...

Страница 6: ...10MHz REF 10MHz TCXO POW ER REG USB REF OUT FRONT PANEL REF IN RF OUT 5VDC 15VDC 15VDC Figure 1 HMC T2000 Block Diagram 4 Installation of Equipment and Safety The bulleted guidelines shown below must...

Страница 7: ...etup and Operation Before the SG unit can be operated external coaxial cables equipment and instrumentation are required to be set up The instruction steps listed below must first be completed 1 Use a...

Страница 8: ...tor for the RF output See figure 2 for a view of the front panel The rear panel of the unit contains power On Off switch LCD contrast adjustment and the connectors for the External Reference Input Ref...

Страница 9: ...ment frequency with 1 MHz steps 2 Increment Decrement frequency with 10 MHz steps 3 Increment Decrement frequency with 100 MHz steps 4 Increment Decrement Output Power with 0 5 dBm steps Rotation of t...

Страница 10: ...s below for descriptions and illustrations of the power level indicators 5 2 3 2 Un calibrated Output Power The character is displayed next to the power level when the output power selected by the use...

Страница 11: ...he RF Output ON OFF status indicator See figure 6 below Figure 6 Minimum output power indicator 5 2 4 USB Connector The USB connector is located on the rear panel The USB interface is compliant with U...

Страница 12: ...specified in the datasheet on the Hittite website 5 2 5 2 External Reference The internal reference can be overridden by connecting an external reference to the BNC connector located on the rear pane...

Страница 13: ...5 non condensing Altitude Less than 3000 meters Table 4 Environmental Operating Conditions 5 4 Air Inlet The unit utilizes convection cooling Please ensure that the vent openings are not obstructed or...

Страница 14: ...y be accessed by pointing to the GUI and performing a Right Click with the mouse The functions available from this menu are ReMap Hardware Open Close Refresh and Disable Power Checks The top right pul...

Страница 15: ...r after the application has been started use the ReMap Hardware function to force the software to check for other synthesizers 5 5 4 Remote and Local Lockout The Remote and Local Lockout feature is en...

Страница 16: ...ication The Remote and Local Lockout checkbox must be selected in order for any of the sweep functions to be enabled 5 5 8 1 Single Sweep Start Continuous Sweep When the Single Sweep button is pressed...

Страница 17: ...provided to enter the value of the Dwell Time for each step in the sweep Valid values for this field are 0 001 secs to 3600 secs The value may be entered by typing the desired value or using the up a...

Страница 18: ...HMC T2000 User s Manual HMC119983 Rev 1 16 Select Next This window will be displayed during the install process This window shows status of the install...

Страница 19: ...HMC T2000 User s Manual HMC119983 Rev 1 17 The software is being installed Select Continue Anyway...

Страница 20: ...HMC T2000 User s Manual HMC119983 Rev 1 18 Select Finish Select Next...

Страница 21: ...983 Rev 1 19 Select the desired folder name and location and select whether you want anyone who uses this computer to be able to run the application The default folder location is recommended Select N...

Страница 22: ...HMC T2000 User s Manual HMC119983 Rev 1 20 This window is displayed to show installation progress Select Close...

Страница 23: ...HMC T2000 User s Manual HMC119983 Rev 1 21 Select OK Select the Program Group for installation Hittite is the recommended group...

Страница 24: ...ge the install directory if desired and then select the large button on the top left It is recommended that the installation is to the default directory This window indicates that the installer for th...

Страница 25: ...progress Select Close The installation of all software components is done 6 Maintenance The unit should be calibrated every 12 months The unit is provided with calibration software so that the user c...

Страница 26: ...ied with a Hittite software application to support the calibration of the unit s output power A picture of the GUI is shown in figure 8 The software will provide information related to the required eq...

Страница 27: ...amount of attenuation between at the output of the HMC T2000 and the Power Meter 6 Verify power is ON to the HMC T2000 and select Initialize T2000 and verify the following window appears 7 Select OK...

Страница 28: ...HMC T2000 User s Manual HMC119983 Rev 1 26 Select OK Select OK Select OK 10 Select Yes to begin calibration...

Страница 29: ...aim or cause of action that might otherwise arise out of the purchase and use of seller s products or service Seller shall not be liable for special or consequential damages of any nature with respect...

Отзывы: