UG-1673
Rev. 0 | Page 13 of 29
Access the direct register read/write function on the right side
of the
Activity Log
section. To access this function, slide the
arrow to the left to expose it (see Figure 21).
22009-
021
Figure 21.
Activity Log
Section Register Access
CLOCK PIN CONTROL TAB
Use this tab to control which clock is applied to the
GP_CLK/RX_ER/MDIX_MODE pin (see Figure 22).
22009-
022
Figure 22.
Clock Pin Control
Tab
LOOPBACK TAB
The various loopback modes are available in this tab (see
Figure 23). Consult the
data sheet for a full
description of each loopback mode.
22009-
023
Figure 23.
Loopback
Tab
TEST MODES TAB
Use this tab to initiate the various test mode functions in the
device. Select the appropriate test mode and click
Execute Test
22009-
024
Figure 24.
Test Modes
Tab
FRAMEGENERATOR/CHECKER
This tab provides access to the frame generator and frame
checker features of the
Control the number of frames generated by the generator, the
frame length, and the content of the frame within this tab.
Choose to have the frame generator to either run in burst mode
or run continuously. To halt the frame generator when the frame
generator is running continuously, use the
Terminate
button.
Use the
Remote
button to enable the remote device to loop
back the data to the local device. To ensure that the appropriate
device is selected, choose which connected board is the local,
configure that board to generate frames, then configure the
other board in remote loopback.
22009-
025
Figure 25. Overview of Frame Generator and Frame Checker