Evaluation Board User Guide
UG-154
Rev. 0 | Page 7 of 16
HARDWARE CONFIGURATION
To configure the hardware, follow these steps:
1.
If the hardware is not already connected, plug the USB A to
Mini-B cable into the PC.
2.
Connect the ISEB to the USB cable.
3.
If prompted to install the device, see the Downloading All
Files to a PC section for details on how to install and select
the correct driver.
4.
Ensure that the jumpers on the ADXRS800 satellite are in
their default configuration, as shown in Figure 15. This sets
up the board to use the on-board boost converter to
generate the required high voltage supply for the device.
For more information on using alternate high voltage
supplies, see the ADXRS800 data sheet and the Alternate
External High Voltage Supply section of this guide.
ANALOG DEVICES
ADXRS800 SATELLITE
DEFAULT
JUMPER
POSITIONS
CO
NNE
C
T
OR
09113-
015
Figure 15. Default Jumper Positions
5.
Connect the ISEB to the ADXRS800 satellite using the
18-inch, 20-pin ribbon cable. This cable is keyed to prevent
inserting it backward and causing damage to the system.
6.
Connect the ADXRS800 satellite to the opposite end of the
ribbon cable.
The inertial sensor evaluation system should now be set up and
ready to use and should resemble the setup shown in Figure 16.
09113-
016
Figure 16. Fully Assembled Evaluation Kit