CAN0 Interface
1-10
ADSP-CM403F EZ-KIT Lite Evaluation System Manual
CAN0 Interface
The Controller Area Network 0 (
CAN0
) interface of the EZ-KIT Lite is
connected to the Analog Devices ADM3053 isolated CAN transceiver
(
U26
). The transceiver is attached to the
CAN0
port of the ADSP-CM403F
processor via an RJ-11 connector (
J8
). See
The EZ-KIT Lite voltage isolation components are not intended
for protecting external products. The isolated ICs are used to show-
case Analog Devices product portfolio only. Adequate voltage
isolation of any external devices/boards is the user responsibility.
The CAN0 transmit and receive signals are connected through the Soft-
Config switches and enabled by default. See
For more information, refer to the CAN0 example in the POST, which is
included in the ADSP-CM40x Enablement Software.
Debug Interface
The EZ-KIT Lite provides a JTAG/SWD/SWV connection via a connec-
tor (
P1
), which is a 0.1” header. A 4-bit trace connection also includes
JTAG/SWD/SWV and is available via a connector (
P2
). See
Serial Liquid Crystal Display Module
Interface
Connector
J3
mates with the Newhaven Display International
NHD-0220D3Z-FL-GBW-V3, a 2-line by 20-character display with a
yellow/green backlight.