28
#L010120
November 2001
I - Read Inputs
Format: I
Description: This command returns the binary value of the inputs to the PC. Since the inputs
are pulled up internally, they will return a high when they are pulled low. For
example, if all inputs are active (grounded), the command will return a 15. If all
inputs are inactive (open), the command will return a 0. Input 1 is the LSB, input
2 is the second bit, input 3 is the third bit, and input 4 is the MSB.
O - Set Outputs
Format:
O [value]
Description: This command sets the outputs according to the binary value. Output 1 is the
LSB and output 2 is the MSB.
Range:
0 - 3
V - Verify
Format:
V [command]
Description: This command can be used with most commands to verify the register contents.
This is a read only command. Valid Commands are: A, B, F, J, M, N, 0, P, Z, and
+.
L0 - Get Limit Status
Format: L0
Description: This command returns the binary value of the hard and soft in a binary format.
The soft limit is the LSB and the hard limit is the MSB.
LS - Soft Limit Input Bit
Format: LS
Description: This command will ramp the clocks down to base speed. The move type then de-
termines what will happen. In a relative or absolute type motion the PCL501(PC)
will continue to the set position and stop. In a slew type motion the PCL501(PC) will
ramp down and stop.