P - Absolute Position
Format:
P [value]
Description: This command calculates and sets the number of steps necessary to move to the
specified position. (N=P-Z)
Range:
-8388608 - 8388607
N - Number of Steps
Format:
N [value]
Description: This command sets the number of clocks for the PCL501(PC) to send out follow-
ing
a G command.
Range:
0 - 8388607
G - Go Number of Steps
Format: G
Description: This command is used to send a set number of clocks out of the PCL501(PC).
An N or P command must be entered before the G command.
S - Go Slew
Format :
S
Description: This command will send clocks out to the PCL501(PC). The only commands that
can stop the clocks are; . (stop motion) or LS (soft limit). Motion can also be
stopped by using the limit switch inputs. The ramp profile is specified by the B
(base speed), M (max speed), and A (acceleration/deceleration) commands.
J - Jog Speed
Format:
J [value]
Description: This command sets the jog speed. This value must be greater than the base speed.
Range:
77 - 15000