27
#L010120
November 2001
H - Home
Format:
H [binary]
Description: This command sends clocks out of the PCL501(PC) until the home limit or the
soft
limit is active. There are two types of homing available.
Home Types: H0: In type 0 homing, the PCL501(PC) will send clocks until a soft limit is
reached,
then ramp down to base speed. Clocks will continue until a
home or hard
limit is reached.
H1:
In type 1 homing, the unit will move until a home limit is reached, then
change directions, ramp down to base speed and stop upon release of the
home
limit
input.
Z - Position
Format:
Z [number]
Description: This command sets the current position as a reference. This register can contain
a positive or negative value but cannot be changed while motion is in progress.
Range:
-8388608 to +8388607
. - Stop Motion
Format: .
Description: This command will stop all motion. It can also be used to stop the current pro-
gram
that is running.
+ - Clockwise
Format:
+
Description: This command sets the direction output to clockwise.
- - Counter-Clockwise
Format: -
Description: This command sets the direction output to counterclockwise.
July 2018
L010121