background image

17

18

FAULT PROTECTION

TORQUE/SPEED CURVES

The MDM60001 is internally protected against over temperature, over/under voltage, and
short circuits.
The over temperature set point is between 60C and 70

E

C.

  Care should be taken when

choosing a heatsink so that there is good thermal flow, otherwise hot spots may occur in
the MDM60001 which will reduce the effectiveness of the thermal protection.

The short circuit protection consists of PHASE to PHASE, PHASE to GROUND, and +V
to PHASE.

In the condition where the DC voltage of the driver drops below +23 volts the driver’s
output stage will be disabled.  When the driver’s DC voltage rises back above 24 volts, the
driver will automatically re-enable the outputs (if previously enabled).

In the condition where the DC voltage of the driver exceeds approximately 82 volts, the
driver will execute a  fault.

If any fault is detected by the MDM60001, the outputs will be disabled and can not be re-
enabled without resetting or powering down the driver.  At the same time the open collector
FAULT output is turned on.

The FAULT output is non-isolated and has the ability to sustain the maximum driver
voltage.  It is capable of sinking up to 25mA which can be used to drive a small relay or
LED.

OVER TEMPERATURE PROTECTION

The MDM60001 microstepper is a power device and is designed to protect itself from
overheating.  It does this by monitoring the surface temperature of the drive plate and will
automatically shutdown if the temperature reaches 60°C (152°F).

To prevent nuisance shutdowns, proper heatsinking is required to limit the temperature at
the drive plate.

A thermal grease or thermal pad should be used between the drive plate and the mounting
surface of the heatsink.  The fins of the heatsink should be mounted vertically with at least
3" of space below and above the heatsink for efficient cooling.

In some applications fan cooling will be required to maintain the plate temperature below
the 60°C shutdown temperature.  

Содержание MDM60001

Страница 1: ...roduct may directly threaten life or injury Per Anaheim Automation s Terms and Conditions of Sales the user of Anaheim Automation products in life support applications assumes all risks of such use an...

Страница 2: ...hase at 75 Volts providing outstanding motor performance This advanced technology reduces ripple current while maintaining the 20kHz chopping frequency in the motor causing less heat in both the motor...

Страница 3: ...iption 1 Clock A positive going edge on this isolated input advances the motor one increment The size of the increment is dependent on the Microstep Select Inputs of Switch 1 2 Direction This isolated...

Страница 4: ...depend on the value of the resistor used 2 Current Adjust Phase Current Adjustment input A resistor connected between this input and the ground input connector P2 Pin 3 is used to adjust the maximum...

Страница 5: ...sed to set the output current of the MDM60001 This sets the peak output current of the sine cosine waves The specified motor current which is the RMS value is multiplied by a factor of 0 7 1 0 or 1 4...

Страница 6: ...en pins 1 and 2 of connector P2 the length of the leads should be as short as possible to help minimize noise coupled into the driver MOTOR SELECTION The MDM60001 is a Bipolar driver working equally w...

Страница 7: ...f the motor with respect to the direction input will depend on the connection of the motor windings To reverse the direction of the motor with respect to the direction input switch the wires on Phase...

Страница 8: ...ries Coil Configurations The number of microsteps per step is selected by the internal dip switches settings for these switches The standard waveforms are sinusoidal Resolution Steps Switch 1 Switch 2...

Страница 9: ...ed the MDM60001 will simply take throughput the next step This feature works as an automatic debounce for the Direction and Microstep This high speed MOSFET output is non isolated and has the ability...

Страница 10: ...001 the outputs will be disabled and can not be re enabled without resetting or powering down the driver At the same time the open collector FAULT output is turned on The FAULT output is non isolated...

Страница 11: ...TORQUE SPEED CURVES Notes...