Anaheim Automation MDM60001 Скачать руководство пользователя страница 6

9

10

RMS  Reduction Current (Amps)=(.707)(.002)xR(Adjust)xR(Reduction)
                                                                 R(R(Reduction)

REDUCING OUTPUT CURRENT

STEP MOTOR CONFIGURATIONS

Reducing the output current in the MDM60001 can be accomplished by connecting an

currents.  Shown below are different lead configurations and the procedures to determine

external resistor (1/8 watt or higher) between pins 1 and 2 of connector P2 and ocurrs

their output current.

automatically 1 second after the last positive going edge of the step clock input.  See Figure
1 for TYPICAL HOOK-UP.

The amount of current per Phase in the reduction mode is related to the value of the current

When configuring a 6 lead motor in a 

half-coil configuration

 (connected from one end of

adjustment resistor and the current reduction resistor.  When the current reduction circuit

the coil to the center tap) use the specified per Phase (or unipolar) current rating to

is activated, the current reduction resistor is paralleled with the current adjustment resistor.

determine the current adjustment resistor value.  This configuration will provide more

This lowers the total resistance value, and thus lowers the per Phase output current.  The

torque at higher speeds.  Use this to determine the current adjustment resistor value.

relationship between the output current and the resistor's value is as follows:

NOTE

: When connecting the current reduction resistor between pins 1 and 2 of connector

 P2 , the length of the leads should be as short as possible to help minimize noise coupled
into the driver.

MOTOR SELECTION

The MDM60001 is a Bipolar driver working equally well with both Bipolar and Unipolar
Motor Configurations,( i.e. 8 and 4 lead motors and 6 lead center tapped motors).

Motors with low current ratings and high inductance will perform better at low speeds,
providing higher low-end torque. Motors with high current ratings and low inductance will
perform better at higher speeds, providing higher high-end torque. 

Since the MDM60001 is a constant current source, it is not necessary to use a motor that
is rated at the same voltage as the supply voltage.  What is important is that the
MDM60001 is set to the appropriate current level based on the motor being used.

Higher voltages will cause the current to flow faster through the motor coils.  This in turn
means higher step rates can be achieved.  

Care should be taken not to exceed the maximum

voltage of the driver.

Step motors can be configured as 4, 6, or 8 leads.  Each configuration requires different

6 Lead Motors 

When configuring the motor in a 

series configuration

 (connected from end to end with the

center tap floating) multiply the per Phase (or unipolar) current rating by 0.7.Use this result
to determine the current adjustment resistor value.

WARNING!

 Step motors will run hot even when configured correctly, damage may occur

to the motor if a higher than specified current is used.  Most specified motor currents are
maximum values.  Care should be taken to not exceed these ratings.

Содержание MDM60001

Страница 1: ...roduct may directly threaten life or injury Per Anaheim Automation s Terms and Conditions of Sales the user of Anaheim Automation products in life support applications assumes all risks of such use an...

Страница 2: ...hase at 75 Volts providing outstanding motor performance This advanced technology reduces ripple current while maintaining the 20kHz chopping frequency in the motor causing less heat in both the motor...

Страница 3: ...iption 1 Clock A positive going edge on this isolated input advances the motor one increment The size of the increment is dependent on the Microstep Select Inputs of Switch 1 2 Direction This isolated...

Страница 4: ...depend on the value of the resistor used 2 Current Adjust Phase Current Adjustment input A resistor connected between this input and the ground input connector P2 Pin 3 is used to adjust the maximum...

Страница 5: ...sed to set the output current of the MDM60001 This sets the peak output current of the sine cosine waves The specified motor current which is the RMS value is multiplied by a factor of 0 7 1 0 or 1 4...

Страница 6: ...en pins 1 and 2 of connector P2 the length of the leads should be as short as possible to help minimize noise coupled into the driver MOTOR SELECTION The MDM60001 is a Bipolar driver working equally w...

Страница 7: ...f the motor with respect to the direction input will depend on the connection of the motor windings To reverse the direction of the motor with respect to the direction input switch the wires on Phase...

Страница 8: ...ries Coil Configurations The number of microsteps per step is selected by the internal dip switches settings for these switches The standard waveforms are sinusoidal Resolution Steps Switch 1 Switch 2...

Страница 9: ...ed the MDM60001 will simply take throughput the next step This feature works as an automatic debounce for the Direction and Microstep This high speed MOSFET output is non isolated and has the ability...

Страница 10: ...001 the outputs will be disabled and can not be re enabled without resetting or powering down the driver At the same time the open collector FAULT output is turned on The FAULT output is non isolated...

Страница 11: ...TORQUE SPEED CURVES Notes...

Страница 12: ...Notes...