Appendix B: Radia Lighting Programming
87
RE-DM4 and RE-DM6 RADIA Eclipse Dimmer Modules
Phase Query
This function queries the current state of the phase detection system. Phase zero-crossing detection
occurs at all times. In the presence of a phase/zero-cross error, the AXLink LED will blink very fast
(>10Hz) and all string responses (where existent) will be "PHASE ERROR!!".
Version Query
This function queries the Radia for its firmware version.
Factory Default
This function commands the Radia to restore all factory defaults.
Phase Query
String:
[<pack>]Y
Response:
P<pack>: <pass/fail> 1<state1> 2A<state2A> 2B<state2B> 3<state3>
The <pass/fail> item will either be 'OK' or 'FAIL' to indicate an overall condition. The <state> items are
phase specific to indicate which phase is failing. The <state> will either be 'Y' for okay or 'N' failure.
Example:
SEND_STRING Radia,"'Y',13"
check phase status
Response: "12,'P01: OK 1Y 2AN 2BN
3N',13,10,'?'"
Good response
SEND_STRING Radia,"'Y',13"
check phase status
Response: "12,'P01: FAIL 1Y 2AN 2BN
3Y',13,10,'?'"
Fail on 2A and 2B
Version Query
String:
<pack>VER
Response:
P<pack> <version string>
Example:
SEND_STRING Radia,"'VER',13"
Request version
Response: "12,'P01 v3.14',13,10,'?'"
If <p> is specified, it must be 1 (e.g. 1Y).
Factory Default
String:
FACTORY
Response:
None
Example:
SEND_STRING Radia,"'FACTORY',13"
Restore Factory Defaults
Response: None
Содержание Radia RE-DM6
Страница 16: ...Radia Eclipse RE DM6 Dimmer Module 10 RE DM4 and RE DM6 RADIA Eclipse Dimmer Modules ...
Страница 20: ...AMX Lighting Systems 14 RE DM4 and RE DM6 RADIA Eclipse Dimmer Modules ...
Страница 48: ...AMX Lighting Programming 42 RE DM4 and RE DM6 RADIA Eclipse Dimmer Modules ...
Страница 102: ...Appendix C Troubleshooting 96 RE DM4 and RE DM6 RADIA Eclipse Dimmer Modules ...
Страница 103: ...Appendix C Troubleshooting 97 RE DM4 and RE DM6 RADIA Eclipse Dimmer Modules ...