Appendix A: AMX Lighting Curves
47
RE-DM4 and RE-DM6 RADIA Eclipse Dimmer Modules
The following table provides a general relationship between load type and which curve to use:
Standard Dimming Curve (1)
FIG. 40 shows the curve 1 voltage output in 120 volts DC.
Load Type
Curves
Incandescent
Curve 1 – Standard dimming curve
Curve 2 – Energy efficient, uses 10% less energy.
Advance Mark VII Ballast
Curves 3, 5, or 6
4-wire Ballasts
Curve 5 – Used for some ballasts
Curve 7 – Used with other ballasts with the RDM-DC series of modules.
Low voltage
Curves 5, 6, B, C – All logarithmic curves with slight variations in the
curve.
Lutron FDB Ballasts
Curve 8 – Used in conjunction with the RDM-FDB series of modules.
Curve 9 – Used in conjunction with the RDM-FDB series of modules.
Provides a slightly different “look” than curve 8. Since this curve has the
highest low end turn-on level by default, it is probably a good choice for
Advance Mark X. We have found the Mark X usually needs its low-end
setting adjusted higher.
Non-dimming/Switched
Curve N, Curve E – Used for ON/OFF control only. Useful for all switch
modules (i.e. RDM-SWM, RDM-HSW, RDM-DPSM, RDM-ZC modules).
Fan motors
Curve R - Used for devices that start at a high voltage and then decrease
voltage in order to function.
FIG. 40
Curve 1 Voltage output in 120 Volts AC
Содержание Radia RE-DM6
Страница 16: ...Radia Eclipse RE DM6 Dimmer Module 10 RE DM4 and RE DM6 RADIA Eclipse Dimmer Modules ...
Страница 20: ...AMX Lighting Systems 14 RE DM4 and RE DM6 RADIA Eclipse Dimmer Modules ...
Страница 48: ...AMX Lighting Programming 42 RE DM4 and RE DM6 RADIA Eclipse Dimmer Modules ...
Страница 102: ...Appendix C Troubleshooting 96 RE DM4 and RE DM6 RADIA Eclipse Dimmer Modules ...
Страница 103: ...Appendix C Troubleshooting 97 RE DM4 and RE DM6 RADIA Eclipse Dimmer Modules ...