Appendix B: AMX Lighting Curves
46
AMX Lighting PROlink/AXlink Programming
FIG. 24 shows the output voltage of the RAD-VDR module. Curve 4 is primarily used for control
of Prescolite Intelect Ballast, using the RAD-VDR module. Its range is from 1 to 12 VDC.
FIG. 25 shows the output voltage of a RAD-MC120 dimmer. It quickly dims the high end and
extends the mid-range dimming control with a cut-off at 18 volts. This curve can be useful with two
wire dimmable fluorescent ballasts.
!
Relay turn on level = 1%
!
Dimming Range = 16 - 120 VAC.
FIG. 26 shows the output voltage of Curve 5 applied to the RAD-VDR module. It turns on to about
2 volts and rises to 12 VDC. There is a large increase in output above 98%.
FIG. 24
Curve 4 Voltage output in volts DC
FIG. 25
Curve 5 Voltage output in Volts RMS
FIG. 26
Curve 5 Voltage output in volts DC