Appendix B: AMX Lighting Curves
43
AMX Lighting PROlink/AXlink Programming
FIG. 16 shows the dimmer turning on to level 20 from an off condition. It maintains the level until
the dimmer reaches a level above 20%, at which point the dimmer output starts to climb again.
Conversely, it will dim down to 20% and maintain that level until it turns off.
!
Relay turn on level = 1%
!
Dimming Range = 56 - 120 VAC.
FIG. 17 shows the low-voltage output of the RAD-VDR module. The voltage range is 4 to 12 VDC
when attached to test ballast.
FIG. 18 shows three different Low End Settings of 5%, 10%, and 20%. Each curve holds its
assigned value until the dimmer level reaches 0. Ramping up from level 0 will turn on the lamps at
three different levels respectively. Low End settings can be used to correct for problems in dimming
various lighting products at low levels. Dimming ranges can be controlled using the low end
setting. Curve 1 dimming range is normally 0 -120 VAC, but with a Low End Setting of 5 the range
is reduced to 26 - 120, or a 20% reduction in total dimming range. A Low End Setting of 10%
reduces the range from 40 to 120 VAC or 35% reductions while a Low End Setting of 20 on Curve
1 is about a 50% reduction in dimming range. Small adjustments in a curve can cause significant
changes in a dimmer's response.
FIG. 16
Curve 1 with Low End Setting @ 20% Volts RMS
FIG. 17
Curve 1 voltage output with Low End Setting @ 20 % Volts DC
Содержание ProLink PRO-DP8
Страница 1: ...instruction manual Lighting Control AMX Lighting PROlink AXlink Programming ...
Страница 4: ......
Страница 8: ...iv AMX Lighting PROlink AXlink Programming Table of Contents ...
Страница 14: ...Introduction 6 AMX Lighting PROlink AXlink Programming ...
Страница 22: ...Pre Installation Settings 14 AMX Lighting PROlink AXlink Programming ...
Страница 46: ...Appendix A PROlink vs AXlink Commands 38 AMX Lighting PROlink AXlink Programming ...
Страница 65: ...Appendix C Troubleshooting 57 AMX Lighting PROlonl AXlink Programming ...