![AMX Modero Viewpoint MVP-5200i Скачать руководство пользователя страница 128](http://html.mh-extra.com/html/amx/modero-viewpoint-mvp-5200i/modero-viewpoint-mvp-5200i_operation-reference-manual_2937695128.webp)
Programming
120
MVP-5200i Modero Viewpoint Widescreen Touch Panel
"^" Button Commands
These Button Commands are used in NetLinx Studio and are case insensitive.
All commands that begin with "
^
" have the capability of assigning a variable text address range and
button state range.
A device must first be defined in the NetLinx programming language with values
for the Device: Port : System
(in all programming examples -
Panel
is used in place of these values).
Variable text ranges
allow you to target 1 or more variable text channels in a single
command.
Button State ranges
allow you to target 1 or more states of a variable text button with a single
command.
"."
Character is used for the 'through' notation, also the "
&
" character is used for the 'And'
notation.
"^" Button Commands
^ANI
Run a button
animation
(in 1/10 second).
Syntax:
"'^ANI-<vt addr range>,<start state>,<end state>,<time>'"
Variable:
variable text address range = 1 - 4000.
start state = Beginning of button state (0= current state).
end state = End of button state.
time = In 1/10 second intervals.
Example:
SEND_COMMAND Panel,"'^ANI-500,1,25,100'"
Runs a button animation at text range 500 from state 1 to state 25 for 10 second.
^APF
Add page flip
action to a button
if it does not
already exist.
Syntax:
"'^APF-<vt addr range>,<page flip action>,<page name>'"
Variable:
variable text address range = 1 - 4000.
page flip action =
Stan
[dardPage] - Flip to standard page
Prev
[iousPage] - Flip to previous page
Show
[Popup] - Show Popup page
Hide
[Popup] - Hide Popup page
Togg
[lePopup] - Toggle popup state
ClearG
[roup] - Clear popup page group from all pages
ClearP
[age] - Clear all popup pages from a page with the
specified page name
ClearA
[ll] - Clear all popup pages from all pages
page name = 1 - 50 ASCII characters.
Example:
SEND COMMAND Panel,"'^APF-400,Stan,Main Page'"
Assigns a button to a standard page flip with page name 'Main Page'.
^BAT
Append
non-unicode text.
Syntax:
"'^BAT-<vt addr range>,<button states range>,<new text>'"
Variable:
variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons
1 = Off state and 2 = On state).
new text = 1 - 50 ASCII characters.
Example:
SEND_COMMAND Panel,"'^BAT-520,1,Enter City'"
Appends the text 'Enter City' to the button’s OFF state.
Содержание Modero Viewpoint MVP-5200i
Страница 28: ...Accessories 20 MVP 5200i Modero Viewpoint Widescreen Touch Panel ...
Страница 56: ...Configuring Communication 48 MVP 5200i Modero Viewpoint Widescreen Touch Panel ...
Страница 68: ...Setup Pages 60 MVP 5200i Modero Viewpoint Widescreen Touch Panel ...
Страница 106: ...Protected Setup Pages 98 MVP 5200i Modero Viewpoint Widescreen Touch Panel ...
Страница 174: ...Programming 166 MVP 5200i Modero Viewpoint Widescreen Touch Panel ...
Страница 182: ...Battery Life and Replacement 174 MVP 5200i Modero Viewpoint Widescreen Touch Panel ...