AXlink Data and Power Connections
The Mio Modero IR uses a four-pin mini AXlink connector for power and data.
Connect the control system's AXlink connector to the AXlink connector on the rear
panel of the Mio Modero IR for data and 12 VDC power as shown in FIG. 4.
Checking AXlink Status
The AXlink LED lights to indicate AXlink power/data status as follows:
If the LED is on and not flashing, disconnect the AXlink connector and recheck all
AXlink connections. Then, reconnect the AXlink connector to the panel and verify the
LED is flashing once per second.
Mounting Procedure
AMX recommends mounting the Mio Modero IR in a standard one-gang wallbox, a
conduit box per NEC specs section 370, with a minimum internal clearance of 2-5/8"
x 1-3/4" x 1-5/8" (HWD). More installation details are available in the
Mio Modero
Device Family
instruction manual.
1.
Use the cutout dimension for the wallbox to cutout the install surface for the
Mio Modero IR.
2.
Confirm that the terminal end of the AXlink cable is disconnected, and not
receiving power.
3.
If the faceplate is connected to the mounting frame, place a flathead screw-
driver in the notch at the bottom right of the Mio Modero IR, and pry the face-
plate from the mounting frame.
4.
Connect the AXlink power supply. The connector passes through the center of
the mounting frame and connects to the board.
5.
Place the mounting frame on the wallbox; align the screw holes with the mount-
ing holes and fasten the mounting frame to the wallbox using the screws sup-
plied.
6.
Attach the faceplate to the mounting frame first at the top and swing it to the
bottom. See FIG. 6.
FIG. 4
AXlink straight-thru wiring
• 1 blink per
second
Indicates power is active and AXlink communication is working.
• 2 blinks per
second
Indicates the devices specified in the Master program do not
match the devices found.
• 3 blinks per
second
Indicates AXlink communication error.
• Full On
Indicates the following conditions:
• There is no AXlink control or activity, but power is On.
• The Axcess program is not loaded.
FIG. 5
Mio Modero IR mounting dimensions
PWR +
AXP
AXM
GND -
PWR +
AXP
AXM
GND -
Mio Modero
Control System
2.250
[57.2 MM]
[83.4 MM]
3.282
[50.8 MM]
2.000
FIG. 6
Attaching the faceplate to the mounting frame