Installation
20
MXD/T-1901-PAN 19.4" Modero X Series® G5 Touch Panels
12.
Snap the decorative side covers (FIG. 21) onto each end of the touch panel.
13.
Reconnect the terminal Ethernet and USB to their respective locations on the Ethernet port.
Wiring a Power Connection
To use the 2-pin 3.5 mm captive wire connector with a 12 VDC-compliant power supply, the incoming PWR and GND
wires from the external source must be connected to their corresponding locations on the connector (FIG. 22). The
connector uses locking screws to insure a connection to the device, so make sure to insert and tighten the screws before
applying power.
1.
Insert the PWR and GND wires on the terminal end of the 2-pin 3.5 mm captive wire cable.
Match the wiring
locations of the +/- on both the power supply and the terminal connector.
2.
Tighten the clamp to secure the two wires.
Do not tighten the screws excessively; doing so may strip the threads and
damage the connector.
3.
Verify the connection of the 2-pin 3.5 mm captive wire to the external 12 VDC-compliant power supply and apply
power.
FIG. 21
MXD-1901-PAN side cover installation (Landscape)
FIG. 22
NetLinx power connector wiring diagram
MXD-1901-PAN
Screws (3)
Side cover
PWR +
GND -
To the Touch Panel
Power Supply